Thyroid Gland

The category Thyroid Gland encompasses human biospecimens which were measured for the laboratory parameters Thyroglobulin (Tg), Thyrotropin (TSH), Thyroxine (FT4), Thyroglobulin (Tg), Total Thyroxine (TT4), Triiodothyronine (FT3) and TSH Receptor Antibodies (TRAb). Procurement takes place from consented donors under strict ethical standards. Use our filter functions to perform complex searches according to matrices, disease in clear name or ICD-10 code and patient annotation like age, gender, BMI and ethnicity. If you do not find the samples you are looking for, please contact our Central BioHub team.

Available filters
-
-
-
7,921 Products

Human Serum - Anti-Thyroglobulin (aTg / TAK), Anti-... - Self-reported Healthy

Donor:
Gender: Female Age: 30 Ethnic group: European/Caucasian
Medication:
L-thyroxine
Parameter:
Anti-Thyroglobulin (aTg / TAK) Anti-Thyroid peroxidase (aTPO / MAK) Cross-reactive carbohydrate determinants (CCD) SIgE Italian/Mediterranean/Funeral cypress (t23) SIgE Almond (f20) SIgE Alternaria alternata (m6) SIgE Apple (f49) SIgE Apricot (f237) SIgE Aspergillus fumigatus (m3) SIgE Beef (f27) ...
Donor:
Gender:
Female
Age:
30 Years
Ethnic group:
European/Caucasian
BMI:
23 kg/m²
Weight:
60 kg
Height:
160 cm
Sample:
Matrix:
Serum
Condition:
perfect
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Medication:
  • L-thyroxine
  • Microlut
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: < 20.00 kU/L
Source: this donation
< 40.00 kU/L
Method: CLIA (Chemiluminescence Immuno Assay)
System: Immulite Siemens
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: < 10.00 kU/L
Source: this donation
< 35.00 kU/L
Method: CLIA (Chemiluminescence Immuno Assay)
System: Immulite Siemens
Cross-reactive carbohydrate determinants (CCD)
Qual:
Quant: < 0.35 kU/L
Source: this donation
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Italian/Mediterranean/Funeral cypress (t23)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Almond (f20)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Alternaria alternata (m6)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Apple (f49)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Apricot (f237)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Aspergillus fumigatus (m3)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Beef (f27)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Birch (t3)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Carrot (f31)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Cat dander (e1)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Celery (f85)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Cladosporium herbarum (m2)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Cockroach, German (i6)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Cocksfoot (g3)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Common ragweed (w1)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Common wasp (Yellow jacket) (i3)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Crab (f23)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Cultivated rye (g12)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Dermatophagoides farinae (d2)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Dermatophagoides pteronyssinus (d1)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Egg white (f1)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Egg yolk (f75)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Fish (cod) (f3)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Greer Labs., Inc. (h1)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Grey alder (t2)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Hazel (t4)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Hazel nut (f17)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Honey bee (i1)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Horse dander (e3)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Kiwi (f84)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Latex (k82)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Milk (f2)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Mugwort (w6)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Mutton (f88)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Oak (t7)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Peanut (f13)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Penicillium chrysogenum (P. notatum) (m1)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Plantain, Ribwort (w9)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Potato (f35)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Rice (f9)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Rye (f5)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Sesame seed (f10)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Shrimp (f24)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Soybean (f14)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Sweet vernal grass (g1)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Timothy grass (g6)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Tomato (f25)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Wheat flour (f4)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE Yeast (f45)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE dog (e2)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE nBos d 4 alpha-lactalbumin, Milk (f76)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE nBos d 5 beta-lactoglobulin, Milk (f77)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE nBos d 6 BSA, Cow (e204)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
SIgE nBos d 8 Casein, Milk (f78)
Qual:
Quant: < 0.35 kU/L
Source: this donation
Remarks: CAP/RAST/EAST-class:0
< 0.35 kU/L
Method: Immunoblot
System: EUROLineScan-Programm EUROIMMUN AG
Thyrotropin (TSH)
Qual:
Quant: 0.09 mU/L
Source: this donation
Remarks: basal
0.35 - 4.94 mU/L
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: Architect i 2000 sr Abbott Diagnostics
Thyroxine (FT4)
Qual:
Quant: 19.51 pmol/L
Source: this donation
9.01 - 19.05 pmol/L
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: Architect i 2000 not specified
Triglycerides
Qual:
Quant: 4.6 pmol/L
Source: this donation
2.63 - 5.70 pmol/L
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: Architect i 2000 not specified
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH177963
1 mL (€37.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-Gliadin IgG, Anti-Thyroglobulin ... - E55.9

Donor:
Gender: Female Age: 70
Diagnosed disease:
M81.49
Medication:
Cimzia
Parameter:
Anti-Centromere Protein B (CENP-B) Anti-Gliadin IgG Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) ...
Donor:
Gender:
Female
Age:
70 Years
Sample:
Matrix:
Serum
Condition:
perfect
Freeze-Thaw-Cycle:
0
Diseases:
  • Vitamin D deficiency, unspecified [E55.9]
  • Polyarthritis, unspecified [M13.0]
  • M81.49
Medication:
  • Cimzia
  • Enbrel
  • MabThera
  • Orencia
  • RoActemra
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Gliadin IgG
Qual:
Quant: 2 RU/mL
Source: this donation
< 25.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 20 IU/mL
Source: this donation
< 100 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 10 IU/mL
Source: this donation
< 50.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Tissue transglutaminase (tTG) IgA
Qual:
Quant: 2 RU/mL
Source: this donation
< 20.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual:
Quant: 7.4 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual:
Quant: 0.99 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual:
Quant: 0.13 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Rheumatoid Factor (RF) IgA
Qual:
Quant: 91 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual:
Quant: 22 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual:
Quant: 52.5 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0.64 IU/L
Source: this donation
< 1.80 IU/L
Remarks: 1,80 - 2,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH212121
0.8 mL (€90.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-Gliadin IgG, Anti-Thyroglobulin ... - L40.5

Donor:
Gender: Female Age: 61
Diagnosed disease:
M07.0/1/2/3
Medication:
Enbrel
Parameter:
Anti-Centromere Protein B (CENP-B) Anti-Gliadin IgG Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) ...
Donor:
Gender:
Female
Age:
61 Years
Sample:
Matrix:
Serum
Condition:
perfect
Freeze-Thaw-Cycle:
0
Diseases:
  • Arthropathic psoriasis (M07.0-M07.3, M09.0) [L40.5]
  • M07.0/1/2/3
Medication:
  • Enbrel
  • Humira
  • Prolia
  • Remicade
  • Simponi
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Gliadin IgG
Qual:
Quant: 4.18 RU/mL
Source: this donation
< 25.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 20 IU/mL
Source: this donation
< 100 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 10 IU/mL
Source: this donation
< 50.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Tissue transglutaminase (tTG) IgA
Qual:
Quant: 2 RU/mL
Source: this donation
< 20.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: positive
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual:
Quant: 43.1 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual:
Quant: 1.19 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual:
Quant: 0.19 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Rheumatoid Factor (RF) IgA
Qual:
Quant: 3.2 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual:
Quant: 5.5 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual:
Quant: < 1.00 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0.56 IU/L
Source: this donation
< 1.80 IU/L
Remarks: 1,80 - 2,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH215845
0.8 mL (€90.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - 25-Hydroxy-Vitamin D3 (Calcidiol), An... - E55.9

Donor:
Gender: Female Age: 68
Diagnosed disease:
M81.49
Medication:
Cimzia
Parameter:
25-Hydroxy-Vitamin D3 (Calcidiol) Anti-Bone-specific Alkaline Phosphatase (BAP) Anti-SS-A (Ro) Anti-SS-B (La) Anti-Smith (Sm) Anti-Thyroglobulin (aTg / TAK) Anti-Thyroid peroxidase (aTPO / MAK) Anti-U1 small nuclear ribonucleoprotein (U1-snRNP) Anti-double-stranded DNA (dsDNA) Capsule-reactive protein (CRP) ...
Donor:
Gender:
Female
Age:
68 Years
Sample:
Matrix:
Serum
Condition:
perfect
Freeze-Thaw-Cycle:
0
Diseases:
  • Vitamin D deficiency, unspecified [E55.9]
  • Polyarthritis, unspecified [M13.0]
  • M81.49
Medication:
  • Cimzia
  • Enbrel
  • MabThera
  • Orencia
  • RoActemra
Parameter Result Ref. / Cut-Off Measuring Information
25-Hydroxy-Vitamin D3 (Calcidiol)
Qual:
Quant: 38.3 ng/mL
Source: this donation
30.00 - 100 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Anti-Bone-specific Alkaline Phosphatase (BAP)
Qual:
Quant: 14.4 µg/L
Source: this donation
5.50 - 27.10 µg/L
Remarks: sex and age dependent
Method: EIA (Enzyme Immuno Assay)
System: ISYS IDS
Anti-SS-A (Ro)
Qual:
Quant: 1.1 U/mL
Source: this donation
< 25.00 U/mL
Remarks: 15,00 - 25,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-SS-B (La)
Qual:
Quant: 1.5 U/mL
Source: this donation
< 25.00 U/mL
Remarks: 15,00 - 25,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-Smith (Sm)
Qual:
Quant: 1.4 U/mL
Source: this donation
< 25.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 20 IU/mL
Source: this donation
< 100 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 10 IU/mL
Source: this donation
< 5.000 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-U1 small nuclear ribonucleoprotein (U1-snRNP)
Qual:
Quant: 2 U/mL
Source: this donation
< 25.00 U/mL
Remarks: 15,00 - 25,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-double-stranded DNA (dsDNA)
Qual:
Quant: 6.9 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Capsule-reactive protein (CRP)
Qual:
Quant: 9.77 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual:
Quant: 1.03 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual:
Quant: 0.17 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Osteocalcin
Qual:
Quant: 12.9 ng/mL
Source: this donation
10.40 - 45.60 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Parathyroid hormone (PTH)
Qual:
Quant: 30.1 pg/mL
Source: this donation
11.50 - 78.40 pg/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Rheumatoid Factor (RF) IgA
Qual:
Quant: 48.7 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual:
Quant: 22 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual:
Quant: 45.5 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Serum Crosslaps
Qual:
Quant: 0.11 ng/mL
Source: this donation
0.14 - 1.35 ng/mL
Remarks: sex and age dependent
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0.51 IU/L
Source: this donation
< 1.80 IU/L
Remarks: 1,80 - 2,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH220409
0.3 mL (€33.75)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-Gliadin IgG, Anti-Thyroglobulin ... - L40

Donor:
Gender: Female Age: 77
Diagnosed disease:
M07
Medication:
Enbrel
Parameter:
Anti-Centromere Protein B (CENP-B) Anti-Gliadin IgG Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) ...
Donor:
Gender:
Female
Age:
77 Years
Sample:
Matrix:
Serum
Condition:
perfect
Freeze-Thaw-Cycle:
0
Diseases:
  • L40
  • M07
Medication:
  • Enbrel
  • Humira
  • Stelara
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Gliadin IgG
Qual:
Quant: 2 RU/mL
Source: this donation
< 25.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 20 IU/mL
Source: this donation
< 100 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 10 IU/mL
Source: this donation
< 5.000 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Tissue transglutaminase (tTG) IgA
Qual:
Quant: 2 RU/mL
Source: this donation
< 20.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual:
Quant: +
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual:
Quant: 13.6 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual:
Quant: 1.6 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual:
Quant: 0.41 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Rheumatoid Factor (RF) IgA
Qual:
Quant: 5.8 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual:
Quant: 10.2 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual:
Quant: 4 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0.37 IU/L
Source: this donation
< 1.80 IU/L
Remarks: 1,80 - 2,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH218880
0.3 mL (€33.75)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-Neutrophil Cytoplasmic Antibodie... - K29.1

Donor:
Gender: Male Age: 42
Diagnosed disease:
M47.27
Medication:
Inflectra
Parameter:
Anti-Centromere Protein B (CENP-B) Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Neutrophil Cytoplasmic Antibodies (ANCA) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) ...
Donor:
Gender:
Male
Age:
42 Years
Sample:
Matrix:
Serum
Condition:
perfect
Freeze-Thaw-Cycle:
0
Diseases:
  • Other acute gastritis [K29.1]
  • M45.09
  • M47.27
Medication:
  • Inflectra
  • Remicade
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Neutrophil Cytoplasmic Antibodies (ANCA)
Qual: not specified
Quant: not specified Titer
Source: this donation
Remarks: subsequent claim possible
negative Titer
Method: IIFT (Indirect Immunfluorescence Test)
System: iPro EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual:
Quant: 8.8 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 20 IU/mL
Source: this donation
< 100 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 10 IU/mL
Source: this donation
< 50.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual:
Quant: 18.6 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antinuclear Antibodies (ANA)
Qual: not specified
Quant: not specified Titer
Source: this donation
Remarks: subsequent claim possible
negative Titer
Method: IIFT (Indirect Immunfluorescence Test)
System: iPro ORGENTEC Diagnostika GmbH
Capsule-reactive protein (CRP)
Qual:
Quant: 13.4 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual:
Quant: 1.24 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual:
Quant: 0.28 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Rheumatoid Factor (RF) IgA
Qual:
Quant: 4.8 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual:
Quant: 7.6 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual:
Quant: 3 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 2.08 IU/L
Source: this donation
< 1.80 IU/L
Remarks: 1,80 - 2,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH212614
0.5 mL (€56.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-Gliadin IgG, Anti-Nucleosome, An... - M32.1

Donor:
Gender: Female Age: 52
Diagnosed disease:
M81.49
Medication:
Benlysta
Parameter:
Anti-Centromere Protein B (CENP-B) Anti-Gliadin IgG Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) ...
Donor:
Gender:
Female
Age:
52 Years
Sample:
Matrix:
Serum
Condition:
perfect
Freeze-Thaw-Cycle:
0
Diseases:
  • Systemic lupus erythematosus with organ or system involvement [M32.1]
  • M81.49
Medication:
  • Benlysta
  • MabThera
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Gliadin IgG
Qual:
Quant: 2 RU/mL
Source: this donation
< 25.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: positive
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: positive
Quant: very high positive
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: positive
Quant: very high positive
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 208.8 IU/mL
Source: this donation
< 100 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 317.8 IU/mL
Source: this donation
< 50.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Tissue transglutaminase (tTG) IgA
Qual:
Quant: 2 RU/mL
Source: this donation
< 20.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: positive
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: positive
Quant: high positive
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual:
Quant: 4.91 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual:
Quant: 0.84 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual:
Quant: 0.18 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Rheumatoid Factor (RF) IgA
Qual:
Quant: 8.8 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual:
Quant: 5.7 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual:
Quant: 5.2 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0.59 IU/L
Source: this donation
< 1.80 IU/L
Remarks: 1,80 - 2,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH217690
0.6 mL (€67.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-Gliadin IgG, Anti-Thyroglobulin ... - M06.90

Donor:
Gender: Male Age: 59
Diagnosed disease:
M46.8 - Other specified inflammatory spondylopathies
Medication:
Cimzia
Parameter:
Anti-Centromere Protein B (CENP-B) Anti-Gliadin IgG Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) ...
Donor:
Gender:
Male
Age:
59 Years
Sample:
Matrix:
Serum
Condition:
perfect
Freeze-Thaw-Cycle:
0
Diseases:
  • M06.90
  • Other specified inflammatory spondylopathies [M46.8]
Medication:
  • Cimzia
  • Orencia
  • RoActemra
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Gliadin IgG
Qual:
Quant: 2 RU/mL
Source: this donation
< 25.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 20 IU/mL
Source: this donation
< 100 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 10 IU/mL
Source: this donation
< 50.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Tissue transglutaminase (tTG) IgA
Qual:
Quant: 2 RU/mL
Source: this donation
< 20.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual:
Quant: 2.78 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual:
Quant: 1.36 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual:
Quant: 0.31 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Rheumatoid Factor (RF) IgA
Qual:
Quant: < 1 U/mL
Source: this donation
< 20 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual:
Quant: 24.7 U/mL
Source: this donation
< 20 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual:
Quant: 44 IU/mL
Source: this donation
< 20 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0.5 IU/L
Source: this donation
< 1.80 IU/L
Remarks: 1,80 - 2,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH72137
0.6 mL (€67.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - 25-Hydroxy-Vitamin D3 (Calcidiol), Bo... - M05.8

Donor:
Gender: Female Age: 59
Diagnosed disease:
M81.49
Medication:
Enbrel
Parameter:
25-Hydroxy-Vitamin D3 (Calcidiol) Anti-Centromere Protein B (CENP-B) Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) ...
Donor:
Gender:
Female
Age:
59 Years
Sample:
Matrix:
Serum
Condition:
perfect
Freeze-Thaw-Cycle:
0
Diseases:
  • Other seropositive rheumatoid arthritis [M05.8]
  • M81.49
Medication:
  • Enbrel
  • Humira
  • Remicade
Parameter Result Ref. / Cut-Off Measuring Information
25-Hydroxy-Vitamin D3 (Calcidiol)
Qual:
Quant: 31.8 ng/mL
Source: this donation
30.00 - 100 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Bone alkaline phosphatase (BAP)
Qual:
Quant: 21 µg/L
Source: this donation
5.50 - 27.10 µg/L
Remarks: sex and age dependent
Method: EIA (Enzyme Immuno Assay)
System: ISYS IDS
Capsule-reactive protein (CRP)
Qual:
Quant: 10.8 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual:
Quant: 1.3 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual:
Quant: 0.25 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Osteocalcin
Qual:
Quant: 5.3 ng/mL
Source: this donation
10.40 - 45.60 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Parathyroid hormone (PTH)
Qual:
Quant: 45.7 pg/mL
Source: this donation
11.50 - 78.40 pg/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Rheumatoid Factor (RF) IgA
Qual:
Quant: < 1.00 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual:
Quant: 6.3 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual:
Quant: 5.6 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Serum Crosslaps
Qual:
Quant: 0.05 ng/mL
Source: this donation
0.14 - 1.35 ng/mL
Remarks: sex and age dependent
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0.2 IU/L
Source: this donation
< 1.80 IU/L
Remarks: 1,80 - 2,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH212622
0.7 mL (€78.75)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - 25-Hydroxy-Vitamin D3 (Calcidiol), An... - M06.9

Donor:
Gender: Male Age: 48
Diagnosed disease:
M06.9 - Rheumatoid arthritis, unspecified
Medication:
Enbrel
Parameter:
25-Hydroxy-Vitamin D3 (Calcidiol) Anti-Centromere Protein B (CENP-B) Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) ...
Donor:
Gender:
Male
Age:
48 Years
Sample:
Matrix:
Serum
Condition:
perfect
Freeze-Thaw-Cycle:
0
Diseases:
  • Rheumatoid arthritis, unspecified [M06.9]
  • Enbrel intolerance
Medication:
  • Enbrel
  • Humira
Parameter Result Ref. / Cut-Off Measuring Information
25-Hydroxy-Vitamin D3 (Calcidiol)
Qual:
Quant: 30.8 ng/mL
Source: this donation
30.00 - 100 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 20 IU/mL
Source: this donation
< 100 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 10 IU/mL
Source: this donation
< 5.000 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual:
Quant: 14.7 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual:
Quant: 1.32 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual:
Quant: 0.24 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Rheumatoid Factor (RF) IgA
Qual:
Quant: 53.3 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual:
Quant: 222.4 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual:
Quant: > 500 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Serum Crosslaps
Qual:
Quant: 0.61 ng/mL
Source: this donation
0.12 - 0.75 ng/mL
Remarks: sex and age dependent
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0.2 IU/L
Source: this donation
< 1.80 IU/L
Remarks: 1,80 - 2,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH220706
0.7 mL (€78.75)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-Gliadin IgG, Anti-Thyroglobulin ... - M02.-

Donor:
Gender: Male Age: 54
Diagnosed disease:
M45.9
Medication:
Enbrel
Parameter:
Anti-Centromere Protein B (CENP-B) Anti-Gliadin IgG Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) ...
Donor:
Gender:
Male
Age:
54 Years
Sample:
Matrix:
Serum
Condition:
perfect
Freeze-Thaw-Cycle:
0
Diseases:
  • M02.-
  • M45.9
Medication:
  • Enbrel
  • Remicade
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Gliadin IgG
Qual:
Quant: 8.83 RU/mL
Source: this donation
< 25.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 20 IU/mL
Source: this donation
< 100 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 10 IU/mL
Source: this donation
< 5.000 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Tissue transglutaminase (tTG) IgA
Qual:
Quant: 11.65 RU/mL
Source: this donation
< 20.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual:
Quant: 1.21 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual:
Quant: 1.12 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual:
Quant: 0.28 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Rheumatoid Factor (RF) IgA
Qual:
Quant: 6 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual:
Quant: 12.5 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual:
Quant: 9 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0.45 IU/L
Source: this donation
< 1.80 IU/L
Remarks: 1,80 - 2,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH220464
0.8 mL (€90.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-Gliadin IgG, Anti-Nucleosome, An... - D68.8

Donor:
Gender: Female Age: 52
Diagnosed disease:
M32.1 - Systemic lupus erythematosus with organ or system involvement
Medication:
Benlysta
Parameter:
Anti-Centromere Protein B (CENP-B) Anti-Gliadin IgG Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) ...
Donor:
Gender:
Female
Age:
52 Years
Sample:
Matrix:
Serum
Condition:
perfect
Freeze-Thaw-Cycle:
0
Diseases:
  • Other specified coagulation defects [D68.8]
  • Systemic lupus erythematosus with organ or system involvement [M32.1]
Medication:
  • Benlysta
  • MabThera
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Gliadin IgG
Qual:
Quant: 2 RU/mL
Source: this donation
< 25.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: positive
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual:
Quant: 22.5 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: positive
Quant: high positive
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual:
Quant: 22 U/mL
Source: this donation
< 25.00 U/mL
Remarks: 15,00 -25,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-SS-A 52 kDa (Ro 52)
Qual: positive
Quant: high positive
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: positive
Quant: high positive
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual:
Quant: 41.7 U/mL
Source: this donation
< 25.00 U/mL
Remarks: 15,00 -25,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 20 IU/mL
Source: this donation
< 100 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 10 IU/mL
Source: this donation
< 50.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Tissue transglutaminase (tTG) IgA
Qual:
Quant: 2 RU/mL
Source: this donation
< 20.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual:
Quant: 21.4 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antinuclear Antibodies (ANA)
Qual: not specified
Quant: not specified Titer
Source: this donation
Remarks: subsequent claim possible
negative Titer
Method: IIFT (Indirect Immunfluorescence Test)
System: iPro ORGENTEC Diagnostika GmbH
Capsule-reactive protein (CRP)
Qual:
Quant: 4.59 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual:
Quant: 1.07 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual:
Quant: 0.33 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Rheumatoid Factor (RF) IgA
Qual:
Quant: 8.4 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual:
Quant: < 1.00 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual:
Quant: < 1.00 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 1.05 IU/L
Source: this donation
< 1.80 IU/L
Remarks: 1,80 - 2,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH215351
0.8 mL (€90.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - 25-Hydroxy-Vitamin D3 (Calcidiol), An... - M13.0

Donor:
Gender: Female Age: 68
Diagnosed disease:
M80.40
Medication:
Enbrel
Parameter:
25-Hydroxy-Vitamin D3 (Calcidiol) Anti-Bone-specific Alkaline Phosphatase (BAP) Anti-Centromere Protein B (CENP-B) Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) ...
Donor:
Gender:
Female
Age:
68 Years
Sample:
Matrix:
Serum
Condition:
perfect
Freeze-Thaw-Cycle:
0
Diseases:
  • Polyarthritis, unspecified [M13.0]
  • M80.40
Medication:
  • Enbrel
  • Humira
  • Orencia
  • Prolia
Parameter Result Ref. / Cut-Off Measuring Information
25-Hydroxy-Vitamin D3 (Calcidiol)
Qual:
Quant: 33.2 ng/mL
Source: this donation
30.00 - 100 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Anti-Bone-specific Alkaline Phosphatase (BAP)
Qual:
Quant: 6.8 µg/L
Source: this donation
5.50 - 27.10 µg/L
Remarks: sex and age dependent
Method: EIA (Enzyme Immuno Assay)
System: ISYS IDS
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 929.6 IU/mL
Source: this donation
< 100 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 27.4 IU/mL
Source: this donation
< 50.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual:
Quant: 4.02 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual:
Quant: 1.1 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual:
Quant: 0.24 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Osteocalcin
Qual:
Quant: 4.3 ng/mL
Source: this donation
10.40 - 45.60 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Parathyroid hormone (PTH)
Qual:
Quant: 38.5 pg/mL
Source: this donation
11.50 - 78.40 pg/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Rheumatoid Factor (RF) IgA
Qual:
Quant: 61.1 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual:
Quant: 240.4 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual:
Quant: 436.3 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Serum Crosslaps
Qual:
Quant: 0.04 ng/mL
Source: this donation
0.14 - 1.35 ng/mL
Remarks: sex and age dependent
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0.42 IU/L
Source: this donation
< 1.80 IU/L
Remarks: 1,80 - 2,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH216204
0.8 mL (€90.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-Gliadin IgG, Anti-PM-Scl, Anti-T... - M05.80

Donor:
Gender: Female Age: 56
Diagnosed disease:
M34.9 - Systemic sclerosis, unspecified
Medication:
Enbrel
Parameter:
Anti-Centromere Protein B (CENP-B) Anti-Gliadin IgG Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) ...
Donor:
Gender:
Female
Age:
56 Years
Sample:
Matrix:
Serum
Condition:
perfect
Freeze-Thaw-Cycle:
0
Diseases:
  • M05.80
  • Polymyositis [M33.2]
  • Systemic sclerosis, unspecified [M34.9]
Medication:
  • Enbrel
  • Humira
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Gliadin IgG
Qual:
Quant: 2 RU/mL
Source: this donation
< 25.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: positive
Quant: low positive
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 20 IU/mL
Source: this donation
< 100 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 10 IU/mL
Source: this donation
< 50.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Tissue transglutaminase (tTG) IgA
Qual:
Quant: 2 RU/mL
Source: this donation
< 20.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual:
Quant: 0.87 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual:
Quant: 0.93 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual:
Quant: 0.16 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Rheumatoid Factor (RF) IgA
Qual:
Quant: 7.2 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual:
Quant: 19.8 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual:
Quant: 3.6 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 1.17 IU/L
Source: this donation
< 1.80 IU/L
Remarks: 1,80 - 2,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH215502
0.9 mL (€101.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-Gliadin IgG, Anti-Thyroglobulin ... - M05.8

Donor:
Gender: Female Age: 52
Diagnosed disease:
M81.40
Medication:
Enbrel
Parameter:
Anti-Centromere Protein B (CENP-B) Anti-Gliadin IgG Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) ...
Donor:
Gender:
Female
Age:
52 Years
Sample:
Matrix:
Serum
Condition:
perfect
Freeze-Thaw-Cycle:
0
Diseases:
  • Other seropositive rheumatoid arthritis [M05.8]
  • M81.40
Medication:
  • Enbrel
  • Kineret
  • RoActemra
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Gliadin IgG
Qual:
Quant: 10.5 RU/mL
Source: this donation
< 25.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 20 IU/mL
Source: this donation
< 100 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 12.03 IU/mL
Source: this donation
< 50.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Tissue transglutaminase (tTG) IgA
Qual:
Quant: 6.45 RU/mL
Source: this donation
< 20.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual:
Quant: 1.31 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual:
Quant: 0.82 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual:
Quant: 0.12 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Rheumatoid Factor (RF) IgA
Qual:
Quant: 25.7 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual:
Quant: 22.1 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual:
Quant: 3.9 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0.71 IU/L
Source: this donation
< 1.80 IU/L
Remarks: 1,80 - 2,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH212495
0.9 mL (€101.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-Neutrophil Cytoplasmic Antibodie... - B00.1

Donor:
Gender: Female Age: 34
Diagnosed disease:
M45.09
Medication:
Cosentyx
Parameter:
Anti-Centromere Protein B (CENP-B) Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Neutrophil Cytoplasmic Antibodies (ANCA) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) ...
Donor:
Gender:
Female
Age:
34 Years
Sample:
Matrix:
Serum
Condition:
perfect
Freeze-Thaw-Cycle:
0
Diseases:
  • Herpesviral vesicular dermatitis [B00.1]
  • M45.09
Medication:
  • Cosentyx
  • Enbrel
  • Humira
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Neutrophil Cytoplasmic Antibodies (ANCA)
Qual: not specified
Quant: not specified Titer
Source: this donation
Remarks: subsequent claim possible
negative Titer
Method: IIFT (Indirect Immunfluorescence Test)
System: iPro EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual:
Quant: 5.3 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-PM-Scl
Qual: positive
Quant: low positive
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 20 IU/mL
Source: this donation
< 100 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 10 IU/mL
Source: this donation
< 50.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual:
Quant: 5.1 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antinuclear Antibodies (ANA)
Qual:
Quant: 0.152777778 Titer
Source: this donation
Remarks: fg
negative Titer
Method: IIFT (Indirect Immunfluorescence Test)
System: IFSprinter EUROIMMUN AG
Antinuclear Antibodies (ANA)
Qual:
Quant: 0.263888889 Titer
Source: this donation
Remarks: Chr
negative Titer
Method: IIFT (Indirect Immunfluorescence Test)
System: IFSprinter EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual:
Quant: 9.92 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual:
Quant: 1.12 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual:
Quant: 0.21 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Rheumatoid Factor (RF) IgA
Qual:
Quant: 5.1 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual:
Quant: 8.1 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual:
Quant: 9.6 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0.2 IU/L
Source: this donation
< 1.80 IU/L
Remarks: 1,80 - 2,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH214986
0.9 mL (€101.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-Thyroglobulin (aTg / TAK), Anti-... - E55.9

Donor:
Gender: Female Age: 69
Diagnosed disease:
M81.49
Medication:
Cimzia
Parameter:
Anti-Centromere Protein B (CENP-B) Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) Anti-SS-B (La) ...
Donor:
Gender:
Female
Age:
69 Years
Sample:
Matrix:
Serum
Condition:
perfect
Freeze-Thaw-Cycle:
0
Diseases:
  • Vitamin D deficiency, unspecified [E55.9]
  • Polyarthritis, unspecified [M13.0]
  • M81.49
Medication:
  • Cimzia
  • Enbrel
  • MabThera
  • Orencia
  • RoActemra
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 20 IU/mL
Source: this donation
< 100 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 10 IU/mL
Source: this donation
< 50.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual:
Quant: 3.33 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual:
Quant: 0.97 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual:
Quant: 0.16 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Rheumatoid Factor (RF) IgA
Qual:
Quant: 13.3 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual:
Quant: 9.6 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual:
Quant: 14.3 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0.51 IU/L
Source: this donation
< 1.80 IU/L
Remarks: 1,80 - 2,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH69008
1.1 mL (€123.75)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-Thyroglobulin (aTg / TAK), Anti-... - E55.9

Donor:
Gender: Female Age: 69
Diagnosed disease:
M81.49
Medication:
Cimzia
Parameter:
Anti-Centromere Protein B (CENP-B) Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) Anti-SS-B (La) ...
Donor:
Gender:
Female
Age:
69 Years
Sample:
Matrix:
Serum
Condition:
perfect
Freeze-Thaw-Cycle:
0
Diseases:
  • Vitamin D deficiency, unspecified [E55.9]
  • Polyarthritis, unspecified [M13.0]
  • M81.49
Medication:
  • Cimzia
  • Enbrel
  • MabThera
  • Orencia
  • RoActemra
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 20 IU/mL
Source: this donation
< 100 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 10 IU/mL
Source: this donation
< 50.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual:
Quant: 2.53 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual:
Quant: 0.92 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual:
Quant: 0.14 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 1.52 IU/L
Source: this donation
< 1.80 IU/L
Remarks: 1,80 - 2,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH146066
1.4 mL (€157.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-Thyroglobulin (aTg / TAK), Anti-... - L40.5

Donor:
Gender: Female Age: 60
Diagnosed disease:
M07.0/1/2/3
Medication:
Enbrel
Parameter:
Anti-Centromere Protein B (CENP-B) Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) Anti-SS-B (La) ...
Donor:
Gender:
Female
Age:
60 Years
Sample:
Matrix:
Serum
Condition:
perfect
Freeze-Thaw-Cycle:
0
Diseases:
  • Arthropathic psoriasis (M07.0-M07.3, M09.0) [L40.5]
  • M07.0/1/2/3
Medication:
  • Enbrel
  • Humira
  • Prolia
  • Remicade
  • Simponi
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 20 IU/mL
Source: this donation
< 100 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 10 IU/mL
Source: this donation
< 50.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual:
Quant: 34.2 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual:
Quant: 1.09 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual:
Quant: 0.16 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Rheumatoid Factor (RF) IgA
Qual:
Quant: 7.2 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual:
Quant: 9.2 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM