Human Plasma Samples

Central BioHub offers Human Plasma Samples in different qualities. So you can clearly see, if a biospecimen is for instance haemolytic or in perfect condition. We offer ACD, Citrate, CPD, CPDA, EDTA, K2 EDTA, K3 EDTA, Na EDTA, Heparin, NaHep, LiHep, K Oxalate and NaF Plasma. To meet your Research and Developement (R&D) needs use further filtering and customize your search for example by laboratory parameters, disease in clear name or ICD-10 code, donor specifications, quantity and price. If you do not find the sample you are looking for, please contact us.

Available filters
-
-
4,410 Products

Human K3EDTA plasma - Anti-Thyroid peroxidase (aTPO / MAK),...

Donor:
Gender: Male Age: 48
Medication:
L-thyroxine
Parameter:
Anti-Thyroid peroxidase (aTPO / MAK) Calcitonin TSH Receptor Antibodies (TRAb) Thyroglobulin (Tg) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Male
Age:
48 Years
Weight:
95 kg
Height:
186 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • hyperthyreosis
  • thyroid carcinoma
Medication:
  • L-thyroxine (specific information from donor: L-thyroxine 175)
Therapy:
  • radioiodine therapy
  • thyroid surgery
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: < 10.00 U/mL
Source: this donation
< 35.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Calcitonin
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Calcitonin
Qual:
Quant: < 2.00 pg/mL
Source: this donation
< 10.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: < 8.00 IU/mL
Source: this donation
< 1.50 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: 44.60 ng/mL
Source: this donation
2.00 - 70.00 ng/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 6.18 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 18.2 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3.12 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH72922
1.1 mL ($50.60)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroid peroxidase (aTPO / MAK),...

Donor:
Gender: Male Age: 51
Medication:
L-thyroxine
Parameter:
Anti-Thyroid peroxidase (aTPO / MAK) Calcitonin TSH Receptor Antibodies (TRAb) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Male
Age:
51 Years
Weight:
78 kg
Height:
182 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Graves disease
Medication:
  • L-thyroxine (specific information from donor: L-thyroxine 112,5)
  • selenium (specific information from donor: selenium 200)
Therapy:
  • radioiodine therapy
  • thyroid surgery
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 1000 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 1617.00 kU/L
Source: this donation
< 35.00 kU/L
Method: not specified
System: Immulite not specified
Measured in: serum
Calcitonin
Qual:
Quant: 2.00 pg/mL
Source: this donation
< 10.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 2.03 IU/L
Source: this donation
< 1.00 IU/L
Method: not specified
System: Gammacounter not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 0.60 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 14.2 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3.91 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 4 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH91319
1 mL ($46.00)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Thyroglobulin (Tg), Thyroglobulin (Tg...

Donor:
Gender: Male Age: 51
Medication:
L-thyroxine
Parameter:
Thyroglobulin (Tg) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Male
Age:
51 Years
Weight:
186 kg
Height:
178 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • thyroid carcinoma
Medication:
  • L-thyroxine (specific information from donor: L-thyroxine 250)
  • Thybon (specific information from donor: Thybon 20)
Therapy:
  • radioiodine therapy
  • thyroid surgery
Parameter Result Ref. / Cut-Off Measuring Information
Thyroglobulin (Tg)
Qual:
Quant: 0.18 ng/mL
Source: this donation
2.00 - 70.00 ng/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: 0.18 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 0.11 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 26.4 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3.55 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 4 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH91883
1 mL ($46.00)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroglobulin (aTg / TAK), Anti-...

Donor:
Gender: Female Age: 53
Medication:
L-thyroxine
Parameter:
Anti-Thyroglobulin (aTg / TAK) Anti-Thyroid peroxidase (aTPO / MAK) TSH Receptor Antibodies (TRAb) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
53 Years
Weight:
72 kg
Height:
164 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Graves disease
Medication:
  • L-thyroxine
  • thiamazole
Therapy:
  • radioiodine therapy
  • thyroid surgery
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 39.00 U/mL
Source: this donation
< 40.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 243.00 U/mL
Source: this donation
< 35.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 2.70 IU/mL
Source: this donation
< 1.50 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 0.40 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 17.00 pg/mL
Source: this donation
8.00 - 18.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 6.00 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH31760
1.2 mL ($55.20)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroglobulin (aTg / TAK), Anti-...

Donor:
Gender: Female Age: 59
Medication:
Thyronajod
Parameter:
Anti-Thyroglobulin (aTg / TAK) Anti-Thyroid peroxidase (aTPO / MAK) Calcitonin TSH Receptor Antibodies (TRAb) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
59 Years
Weight:
110 kg
Height:
160 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • diabetes mellitus type II
  • nodular goiter
Medication:
  • Thyronajod (specific information from donor: Thyronajod 125)
Therapy:
  • thyroid surgery
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: < 8.00 U/mL
Source: this donation
< 40.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 10.00 U/mL
Source: this donation
< 35.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Calcitonin
Qual:
Quant: 2.00 pg/mL
Source: this donation
< 10.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 8.00 IU/mL
Source: this donation
< 1.50 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 1.51 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 13.10 pg/mL
Source: this donation
8.00 - 18.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 13.1 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 2.61 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH88826
1 mL ($46.00)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroglobulin (aTg / TAK), TSH R...

Donor:
Gender: Male Age: 43
Medication:
L-thyroxine
Parameter:
Anti-Thyroglobulin (aTg / TAK) TSH Receptor Antibodies (TRAb) Thyroglobulin (Tg) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Male
Age:
43 Years
Weight:
84 kg
Height:
186 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Graves orbitopathy
  • malignant goiter
Medication:
  • L-thyroxine (specific information from donor: L-thyroxine 175)
Therapy:
  • radioiodine therapy
  • thyroid surgery
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: < 20.00 U/mL
Source: this donation
< 40.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: < 8.00 IU/mL
Source: this donation
< 1.50 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: 0.17 ng/mL
Source: this donation
2.00 - 70.00 ng/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 0.63 mU/L
Source: this donation
0.35 - 4.94 mU/L
Method: not specified
System: Cobas 6000 - Modul e 603 not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 18.10 pg/mL
Source: this donation
8.00 - 18.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3.03 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH26716
1 mL ($46.00)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroid peroxidase (aTPO / MAK),...

Donor:
Gender: Female Age: 34
Medication:
Cefasel
Parameter:
Anti-Thyroid peroxidase (aTPO / MAK) Calcitonin TSH Receptor Antibodies (TRAb) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
34 Years
Weight:
65 kg
Height:
171 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Hashimotos thyroiditis
  • nodular goiter
Medication:
  • Cefasel
Therapy:
  • thyroid surgery
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 28.90 U/mL
Source: this donation
< 35.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 28.9 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Calcitonin
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Calcitonin
Qual:
Quant: < 2.00 pg/mL
Source: this donation
< 10.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: < 8.00 IU/mL
Source: this donation
< 1.50 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 1.50 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 11.2 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3.08 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH15338
1 mL ($46.00)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroid peroxidase (aTPO / MAK),...

Donor:
Gender: Female Age: 48
Medication:
L-thyroxine
Parameter:
Anti-Thyroid peroxidase (aTPO / MAK) Calcitonin TSH Receptor Antibodies (TRAb) Thyroglobulin (Tg) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
48 Years
Weight:
67 kg
Height:
161 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • hypothyroidism
  • thyroid carcinoma
Medication:
  • L-thyroxine (specific information from donor: L-thyroxine 150)
Therapy:
  • thyroid surgery
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 22.80 U/mL
Source: this donation
< 35.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 228 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Calcitonin
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Calcitonin
Qual:
Quant: < 2.00 pg/mL
Source: this donation
< 10.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: < 8.00 IU/mL
Source: this donation
< 1.50 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: < 0.17 ng/mL
Source: this donation
2.00 - 70.00 ng/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 0.04 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 14.9 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 5.54 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 6 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH73755
1.1 mL ($50.60)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroglobulin (aTg / TAK), Anti-...

Donor:
Gender: Female Age: 32
Medication:
Thyronajod
Parameter:
Anti-Thyroglobulin (aTg / TAK) Anti-Thyroid peroxidase (aTPO / MAK) TSH Receptor Antibodies (TRAb) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
32 Years
Weight:
66 kg
Height:
172 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • hypothyroidism
  • struma
Medication:
  • Thyronajod (specific information from donor: Thyronajod 100)
Therapy:
  • thyroid surgery
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 20.70 U/mL
Source: this donation
< 40.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 20.7 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: < 10.00 U/mL
Source: this donation
< 35.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 8.00 IU/mL
Source: this donation
< 1.50 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 1.13 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 10.1 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 10.20 pg/mL
Source: this donation
8.00 - 18.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 2.17 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 2 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH89355
1.2 mL ($55.20)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Calcitonin, Thyrotropin (TSH), Thyrox...

Donor:
Gender: Female Age: 45
Medication:
L-thyroxine
Parameter:
Calcitonin Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
45 Years
Weight:
68 kg
Height:
169 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • hyperthyreosis
  • hypofunction of the parathyroid glands
  • nodular goiter
Medication:
  • L-thyroxine
  • thiamazole
Therapy:
  • thyroid surgery
Parameter Result Ref. / Cut-Off Measuring Information
Calcitonin
Qual:
Quant: 2.00 pg/mL
Source: this donation
< 10.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 3.41 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 14.4 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 2.43 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 2 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH91287
1.2 mL ($55.20)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroid peroxidase (aTPO / MAK),...

Donor:
Gender: Female Age: 36
Medication:
L-thyroxine
Parameter:
Anti-Thyroid peroxidase (aTPO / MAK) Calcitonin TSH Receptor Antibodies (TRAb) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
36 Years
Weight:
68 kg
Height:
174 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Hashimotos thyroiditis
Medication:
  • L-thyroxine (specific information from donor: L-thyroxine 75)
  • selenium (specific information from donor: selenium 200)
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 1000 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 3851.00 kU/L
Source: this donation
< 35.00 kU/L
Method: not specified
System: Immulite not specified
Measured in: serum
Calcitonin
Qual:
Quant: 2.24 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Calcitonin
Qual:
Quant: 2.24 pg/mL
Source: this donation
< 10.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: < 8.00 IU/mL
Source: this donation
< 1.50 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 0.69 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 11.60 pg/mL
Source: this donation
8.00 - 18.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 11.6 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3.01 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH89042
1 mL ($46.00)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroid peroxidase (aTPO / MAK),...

Donor:
Gender: Female Age: 43
Medication:
L-thyroxine
Parameter:
Anti-Thyroid peroxidase (aTPO / MAK) TSH Receptor Antibodies (TRAb) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
43 Years
Weight:
68 kg
Height:
175 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • nodular goiter
Medication:
  • L-thyroxine (specific information from donor: L-thyroxine 125)
  • Rocaltrol (specific information from donor: Rocaltrol 0,25)
  • calcium (specific information from donor: calcium 1000)
Therapy:
  • thyroid surgery
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: < 10.00 U/mL
Source: this donation
< 35.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: < 8.00 IU/mL
Source: this donation
< 1.50 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 0.61 mU/L
Source: this donation
0.35 - 4.94 mU/L
Method: not specified
System: Cobas 6000 - Modul e 603 not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 17.4 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 2.08 pg/mL
Source: this donation
not specified pg/mL
Method: not specified
System: Cobas 6000 - Modul e 601 not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 2 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH91473
1 mL ($46.00)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroglobulin (aTg / TAK), Anti-...

Donor:
Gender: Female Age: 51
Medication:
Propycil
Parameter:
Anti-Thyroglobulin (aTg / TAK) Anti-Thyroid peroxidase (aTPO / MAK) Calcitonin TSH Receptor Antibodies (TRAb) Thyroglobulin (Tg) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
51 Years
Weight:
66 kg
Height:
162 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Graves orbitopathy
Medication:
  • Propycil (specific information from donor: Propycil 5)
Therapy:
  • radioiodine therapy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 0.00 U/mL
Source: this donation
< 40.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 30.50 U/mL
Source: this donation
< 35.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 30.5 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Calcitonin
Qual:
Quant: 2.00 pg/mL
Source: this donation
< 10.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Calcitonin
Qual:
Quant: 2 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 7.98 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 8.00 IU/mL
Source: this donation
< 1.50 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: 0.78 ng/mL
Source: this donation
2.00 - 70.00 ng/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 0.01 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 11.5 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 4.32 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 4 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH30424
1 mL ($46.00)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroid peroxidase (aTPO / MAK),...

Donor:
Gender: Female Age: 38
Medication:
L-thyroxine
Parameter:
Anti-Thyroid peroxidase (aTPO / MAK) Calcitonin TSH Receptor Antibodies (TRAb) Thyroglobulin (Tg) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
38 Years
Weight:
65 kg
Height:
158 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Graves orbitopathy - after thyroid surgery (not specified)
Medication:
  • L-thyroxine (specific information from donor: L-thyroxine 175)
Therapy:
  • thyroid surgery
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 11.40 U/mL
Source: this donation
< 35.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 11.4 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Calcitonin
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Calcitonin
Qual:
Quant: < 2.00 pg/mL
Source: this donation
< 10.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: < 1.00 IU/L
Source: this donation
< 1.00 IU/L
Method: not specified
System: Gammacounter not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: < 0.17 ng/mL
Source: this donation
2.00 - 70.00 ng/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 0.21 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 16.8 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 2.41 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 2 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH74039
1 mL ($46.00)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroglobulin (aTg / TAK), Anti-...

Donor:
Gender: Female Age: 56
Medication:
Euthyrox
Parameter:
Anti-Thyroglobulin (aTg / TAK) Anti-Thyroid peroxidase (aTPO / MAK) Calcitonin TSH Receptor Antibodies (TRAb) Thyroglobulin (Tg) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
56 Years
Weight:
60 kg
Height:
172 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Hashimotos thyroiditis
Medication:
  • Euthyrox (specific information from donor: Euthyrox 137)
  • selenium (specific information from donor: selenium 200)
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: < 20.00 U/mL
Source: this donation
< 40.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: < 10.00 U/mL
Source: this donation
< 35.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Calcitonin
Qual:
Quant: 2.00 pg/mL
Source: this donation
< 10.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 8.00 IU/mL
Source: this donation
< 1.50 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: 1.26 ng/mL
Source: this donation
2.00 - 70.00 ng/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 0.07 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 22.5 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 2.61 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH24534
1 mL ($46.00)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroglobulin (aTg / TAK), Anti-...

Donor:
Gender: Female Age: 56
Medication:
L-thyroxine
Parameter:
Anti-Thyroglobulin (aTg / TAK) Anti-Thyroid peroxidase (aTPO / MAK) TSH Receptor Antibodies (TRAb) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
56 Years
Weight:
122 kg
Height:
174 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Graves disease
Medication:
  • L-thyroxine (specific information from donor: L-thyroxine 74 µg)
  • thiamazole (specific information from donor: thiamazole 5)
Therapy:
  • radioiodine therapy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 13.00 IU/mL
Source: this donation
< 100.00 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 0.00 IU/mL
Source: this donation
< 100.00 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 19.20 U/L
Source: this donation
< 2.00 U/L
Method: not specified
System: RRA not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 7.82 mIU/L
Source: this donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 7.22 pg/mL
Source: this donation
not specified not specified
Method: not specified
System: Cobas 6000 - Modul e 602 not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 2.33 pg/mL
Source: this donation
not specified not specified
Method: not specified
System: Cobas 6000 - Modul e 601 not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH25048
1 mL ($46.00)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroglobulin (aTg / TAK), Anti-...

Donor:
Gender: Female Age: 33
Medication:
Euthyrox
Parameter:
Anti-Thyroglobulin (aTg / TAK) Anti-Thyroid peroxidase (aTPO / MAK) Calcitonin TSH Receptor Antibodies (TRAb) Thyroglobulin (Tg) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
33 Years
Weight:
53 kg
Height:
160 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Graves orbitopathy
Medication:
  • Euthyrox
Therapy:
  • thyroid surgery
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 3.54 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 64.00 U/mL
Source: this donation
< 35.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 64 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Calcitonin
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Calcitonin
Qual:
Quant: < 2.00 pg/mL
Source: this donation
< 10.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: < 8.00 IU/mL
Source: this donation
< 1.50 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: 2.03 ng/mL
Source: this donation
2.00 - 70.00 ng/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: 3.54 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 0.30 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 16.9 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3.17 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH91490
1.1 mL ($50.60)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroid peroxidase (aTPO / MAK),...

Donor:
Gender: Male Age: 28
Medication:
L-thyroxine
Parameter:
Anti-Thyroid peroxidase (aTPO / MAK) Calcitonin TSH Receptor Antibodies (TRAb) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Male
Age:
28 Years
Weight:
95 kg
Height:
179 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • hypothyroidism - latent (not specified)
Medication:
  • L-thyroxine (specific information from donor: L-thyroxine 37,5)
  • selenium
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 51.30 U/mL
Source: this donation
< 35.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 51.3 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Calcitonin
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Calcitonin
Qual:
Quant: < 2.00 pg/mL
Source: this donation
< 10.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: < 8.00 IU/mL
Source: this donation
< 1.50 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 3.72 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 10.9 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3.74 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 4 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH12391
1.1 mL ($50.60)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroglobulin (aTg / TAK), Anti-...

Donor:
Gender: Female Age: 36
Medication:
Levothyroxin
Parameter:
Anti-Thyroglobulin (aTg / TAK) Anti-Thyroid peroxidase (aTPO / MAK) TSH Receptor Antibodies (TRAb) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
36 Years
Weight:
55 kg
Height:
164 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Graves orbitopathy
Medication:
  • Levothyroxin (specific information from donor: Levothyroxin 150)
  • thiamazole
Therapy:
  • radioiodine therapy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 32.00 IU/mL
Source: this donation
< 100.00 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 61.00 IU/mL
Source: this donation
< 100.00 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 6.30 U/L
Source: this donation
< 2.00 U/L
Method: not specified
System: RRA not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 2.70 mIU/L
Source: this donation
0.30 - 4.00 mIU/L
Method: not specified
System: DPC not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 21.80 pmol/L
Source: this donation
11.00 - 23.00 pmol/L
Method: not specified
System: DPC not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 6.30 pmol/L
Source: this donation
2.70 - 7.60 pg/mL
Method: not specified
System: DPC not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH52548
1.1 mL ($50.60)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroglobulin (aTg / TAK), Anti-...

Donor:
Gender: Male Age: 37
Medication:
L-thyroxine
Parameter:
Anti-Thyroglobulin (aTg / TAK) Anti-Thyroid peroxidase (aTPO / MAK) TSH Receptor Antibodies (TRAb) Thyroglobulin (Tg) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Male
Age:
37 Years
Weight:
115 kg
Height:
183 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • nodular goiter
Medication:
  • L-thyroxine (specific information from donor: L-thyroxine 150)
Therapy:
  • thyroid surgery
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 0.00 U/mL
Source: this donation
< 40.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 0.00 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0.00 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: 1.29 ng/mL
Source: this donation
2.00 - 70.00 ng/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 0.49 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 14.9 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 4.00 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH52123
1.1 mL ($50.60)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroglobulin (aTg / TAK), Anti-...

Donor:
Gender: Male Age: 26
Medication:
Levothyroxin
Parameter:
Anti-Thyroglobulin (aTg / TAK) Anti-Thyroid peroxidase (aTPO / MAK) TSH Receptor Antibodies (TRAb) Thyroglobulin (Tg) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Male
Age:
26 Years
Weight:
81 kg
Height:
178 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Graves disease
Medication:
  • Levothyroxin (specific information from donor: Levothyroxin 175)
  • thiamazole
Therapy:
  • radioiodine therapy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 81.00 U/mL
Source: this donation
< 40.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 654.00 U/mL
Source: this donation
< 35.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 11.10 IU/mL
Source: this donation
< 1.50 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: 4.10 ng/mL
Source: this donation
2.00 - 70.00 ng/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 0.07 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 16.74 pg/mL
Source: this donation
8.00 - 18.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3.00 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH10928
1.2 mL ($55.20)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroid peroxidase (aTPO / MAK),...

Donor:
Gender: Female Age: 30
Medication:
L-thyroxine
Parameter:
Anti-Thyroid peroxidase (aTPO / MAK) TSH Receptor Antibodies (TRAb) Thyroglobulin (Tg) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
30 Years
Weight:
86 kg
Height:
171 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • diffuse goiter
Medication:
  • L-thyroxine (specific information from donor: L-thyroxine 175)
Therapy:
  • radioiodine therapy
  • thyroid surgery
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 10.00 U/mL
Source: this donation
< 35.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 8.00 IU/mL
Source: this donation
< 1.50 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: < 0.17 ng/mL
Source: this donation
2.00 - 70.00 ng/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 0.47 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 19 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 2.74 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH15258
1.2 mL ($55.20)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroglobulin (aTg / TAK), Thyro...

Donor:
Gender: Female Age: 51
Medication:
L-thyroxine
Parameter:
Anti-Thyroglobulin (aTg / TAK) Thyroglobulin (Tg) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
51 Years
Weight:
66 kg
Height:
172 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • thyroid carcinoma
Medication:
  • L-thyroxine (specific information from donor: L-thyroxine 175)
Therapy:
  • radioiodine therapy
  • thyroid surgery
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: < 0.17 U/mL
Source: this donation
< 40.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: 0.17 ng/mL
Source: this donation
2.00 - 70.00 ng/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: 0.17 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 0.01 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 23.8 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3.32 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH30800
1.2 mL ($55.20)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroid peroxidase (aTPO / MAK),...

Donor:
Gender: Female Age: 70
Medication:
L-thyroxine
Parameter:
Anti-Thyroid peroxidase (aTPO / MAK) TSH Receptor Antibodies (TRAb) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
70 Years
Weight:
87 kg
Height:
168 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • nodular goiter
Medication:
  • L-thyroxine (specific information from donor: L-thyroxine 75)
Therapy:
  • radioiodine therapy
  • thyroid surgery
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: < 10.00 U/mL
Source: this donation
< 35.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: < 8.00 IU/mL
Source: this donation
< 1.50 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 1.30 mU/L
Source: this donation
0.35 - 4.94 mU/L
Method: not specified
System: Cobas 6000 - Modul e 603 not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 10.8 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 2.21 pg/mL
Source: this donation
not specified pg/mL
Method: not specified
System: Cobas 6000 - Modul e 601 not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 2 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH41630
1.3 mL ($59.80)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroglobulin (aTg / TAK), Anti-...

Donor:
Gender: Female Age: 33
Medication:
Cefasel
Parameter:
Anti-Thyroglobulin (aTg / TAK) Anti-Thyroid peroxidase (aTPO / MAK) Calcitonin TSH Receptor Antibodies (TRAb) Thyroglobulin (Tg) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
33 Years
Weight:
72 kg
Height:
168 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Hashimotos thyroiditis
Medication:
  • Cefasel
  • L-thyroxine (specific information from donor: L-thyroxine 50)
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 0.00 U/mL
Source: this donation
< 40.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: < 10.00 U/mL
Source: this donation
< 35.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Calcitonin
Qual:
Quant: 2.00 pg/mL
Source: this donation
< 10.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 8.00 IU/mL
Source: this donation
< 1.50 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: 6.88 ng/mL
Source: this donation
2.00 - 70.00 ng/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 1.64 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 12.8 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 2.28 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 2 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH15292
1.3 mL ($59.80)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroid peroxidase (aTPO / MAK),...

Donor:
Gender: Female Age: 55
Medication:
L-thyroxine
Parameter:
Anti-Thyroid peroxidase (aTPO / MAK) TSH Receptor Antibodies (TRAb) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
55 Years
Weight:
80 kg
Height:
162 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • nodular goiter
Medication:
  • L-thyroxine (specific information from donor: L-thyroxine 12,5)
  • Thyronajod (specific information from donor: Thyronajod 75)
Therapy:
  • thyroid surgery
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 10.00 U/mL
Source: this donation
< 35.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 8.00 IU/mL
Source: this donation
< 1.50 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 1.56 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 14.50 pg/mL
Source: this donation
8.00 - 18.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3.00 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH24586
1.3 mL ($59.80)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroid peroxidase (aTPO / MAK),...

Donor:
Gender: Female Age: 37
Medication:
L-thyroxine
Parameter:
Anti-Thyroid peroxidase (aTPO / MAK) Calcitonin TSH Receptor Antibodies (TRAb) Thyroglobulin (Tg) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
37 Years
Weight:
114 kg
Height:
170 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • nodular goiter
Medication:
  • L-thyroxine (specific information from donor: L-thyroxine 162,5)
Therapy:
  • thyroid surgery
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 46.80 U/mL
Source: this donation
< 35.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 46.8 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Calcitonin
Qual:
Quant: 2.00 pg/mL
Source: this donation
< 10.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 8.00 IU/mL
Source: this donation
< 1.50 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: < 0.17 ng/mL
Source: this donation
2.00 - 70.00 ng/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 0.21 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 19 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3.50 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 4 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH74528
1.4 mL ($64.40)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroglobulin (aTg / TAK), Anti-...

Donor:
Gender: Female Age: 51
Medication:
L-thyroxine
Parameter:
Anti-Thyroglobulin (aTg / TAK) Anti-Thyroid peroxidase (aTPO / MAK) Calcitonin TSH Receptor Antibodies (TRAb) Thyroglobulin (Tg) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
51 Years
Weight:
65 kg
Height:
170 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Medication:
  • L-thyroxine (specific information from donor: L-thyroxine 50)
Therapy:
  • thyroid surgery
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: < 20.00 U/mL
Source: this donation
< 40.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: < 10.00 U/mL
Source: this donation
< 35.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Calcitonin
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Calcitonin
Qual:
Quant: < 2.00 pg/mL
Source: this donation
< 10.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: < 8.00 IU/mL
Source: this donation
< 1.50 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: 28.90 ng/mL
Source: this donation
2.00 - 70.00 ng/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyroglobulin (Tg)
Qual:
Quant: 28.9 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 0.47 mIU/L
Source: this donation
0.27 - 2.50 mIU/L
Method: not specified
System: not specified not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 14.3 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 2.38 pg/mL
Source: this donation
2.00 - 4.40 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 2 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH30655
1 mL ($46.00)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Triglycerides - Self-reported Healthy

Donor:
Gender: Male Age: 61 Ethnic group: European/Caucasian
Medication:
ASA
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 p24 (HIV-1/2 p24) Hepatitis B Virus surface Antigen (HBsAg) Triglycerides
Donor:
Gender:
Male
Age:
61 Years
Ethnic group:
European/Caucasian
BMI:
28 kg/m²
Weight:
85 kg
Height:
175 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
  • hypertension
Medication:
  • ASA
  • Bisoprolol
  • HCT
  • Ramipril
  • amlodipine
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual: negative
Quant:
Source: this donation
negative
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: Architect i 2000 sr Abbott
Anti-Human Immunodeficiency Virus-1/2 p24 (HIV-1/2 p24)
Qual: negative
Quant:
Source: this donation
negative
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: Architect i 2000 sr Abbott
Hepatitis B Virus surface Antigen (HBsAg)
Qual: negative
Quant:
Source: this donation
negative
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: Architect i 2000 sr Abbott
Triglycerides
Qual:
Quant: 1.26 mmol/L
Source: this donation
< 2.25 mmol/L
Method: not specified
System: AU Beckmann
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH53270
1 mL ($23.00)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)

Human K3EDTA plasma - Anti-Thyroglobulin (aTg / TAK), Anti-...

Donor:
Gender: Female Age: 31
Medication:
Thyronajod
Parameter:
Anti-Thyroglobulin (aTg / TAK) Anti-Thyroid peroxidase (aTPO / MAK) Calcitonin TSH Receptor Antibodies (TRAb) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
31 Years
Weight:
67 kg
Height:
175 cm
Sample:
Matrix:
K3EDTA plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • diffuse goiter
  • thyroid disease - due to iodine deficiencies (not specified)
Medication:
  • Thyronajod (specific information from donor: Thyronajod 50)
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 8.97 U/mL
Source: this donation
< 40.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Anti-Thyroglobulin (aTg / TAK)
Qual:
Quant: 8.97 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Anti-Thyroid peroxidase (aTPO / MAK)
Qual:
Quant: < 10.00 U/mL
Source: this donation
< 35.00 U/mL
Method: not specified
System: DPC Immulite not specified
Measured in: serum
Calcitonin
Qual:
Quant: 2.24 pg/mL
Source: this donation
< 10.00 pg/mL
Method: not specified
System: not specified not specified
Measured in: serum
Calcitonin
Qual:
Quant: 2.36 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: 0 not specified
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
TSH Receptor Antibodies (TRAb)
Qual:
Quant: < 8.00 IU/mL
Source: this donation
< 1.50 IU/mL
Method: not specified
System: not specified not specified
Measured in: serum
Thyrotropin (TSH)
Qual:
Quant: 0.18 mU/L
Source: this donation
0.35 - 4.94 mU/L
Method: not specified
System: Cobas 6000 - Modul e 603 not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 10.75 pg/mL
Source: this donation
not specified pg/mL
Method: not specified
System: Cobas 6000 - Modul e 602 not specified
Measured in: serum
Thyroxine (FT4)
Qual:
Quant: 12.3 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 2.70 pg/mL
Source: this donation
not specified pg/mL
Method: not specified
System: Cobas 6000 - Modul e 601 not specified
Measured in: serum
Triiodothyronine (FT3)
Qual:
Quant: 3 pg/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Measured in: serum
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH13502
1 mL ($46.00)
Supplier: Login to see Will be delivered in 16 to 20 Business Days ($225.00)