Human CPD Plasma Samples

In this category you can find Human CPD Plasma Samples which were measured for laboratory parameters like Anti-Hepatitis C Virus, Hepatitis B Virus surface Antigen, Anti-Malaria or Anti-Human Immunodeficiency Virus-1/2. Procurement takes place from consented donors under strict ethical standards. You can use our filter functions to customise your search. If you do not find the samples you are looking for, please contact our Central BioHub team.

Available filters
-
-
206 Products

Human CPD plasma - Anti-Thyroglobulin (aTg / TAK), Anti-...

Donor:
Gender: Female Age: 40
Medication:
L-thyroxine
Parameter:
Anti-Thyroglobulin (aTg / TAK) Anti-Thyroid peroxidase (aTPO / MAK) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
40 Years
BMI:
30.5 kg/m²
Weight:
79 kg
Height:
161 cm
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Graves disease
  • Hashimotos thyroiditis
  • hypothyroidism
Medication:
  • L-thyroxine
  • selenium (Dosages: 200µg)
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroglobulin (aTg / TAK)
Qual: positive
Quant: 64.70 kU/L
Source: this donation
< 40 kU/L
Method: not specified
System: not specified not specified
Anti-Thyroglobulin (aTg / TAK)
Qual: positive
Quant: 64.7 kU/L
Source: previous donation
< 40 kU/L
Method: CLIA (Chemiluminescence Immuno Assay)
System: Immulite Siemens
Anti-Thyroid peroxidase (aTPO / MAK)
Qual: positive
Quant: 1648.00 kU/L
Source: this donation
< 35 kU/L
Method: not specified
System: not specified not specified
Anti-Thyroid peroxidase (aTPO / MAK)
Qual: positive
Quant: 1648 kU/L
Source: previous donation
< 35 kU/L
Method: CLIA (Chemiluminescence Immuno Assay)
System: Immulite Siemens
Thyrotropin (TSH)
Qual: negative
Quant: 0.73 mIU/L
Source: previous donation
0.27 - 4.2 mIU/L
Method: not specified
System: Cobas e 601 Roche
Thyroxine (FT4)
Qual: negative
Quant: 18.4 pmol/L
Source: previous donation
13 - 23 pmol/L
Method: not specified
System: Cobas 6000 Roche
Triiodothyronine (FT3)
Qual: negative
Quant: 3.4 pmol/L
Source: previous donation
2.8 - 7.1 pmol/L
Method: not specified
System: Cobas 6000 Roche
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH139883
1 mL (€37.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-cyclic citrullinated Peptide (CC... - M05.80

Donor:
Gender: Female Age: 35
Diagnosed disease:
M05.90
Medication:
Enbrel
Parameter:
Anti-cyclic citrullinated Peptide (CCP) / anti-citrullinated Protein Antibodies (ACPA)
Donor:
Gender:
Female
Age:
35 Years
BMI:
21 kg/m²
Weight:
59 kg
Height:
169 cm
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • M05.80
  • M05.90
Medication:
  • Enbrel (Dosages: 50not specified, active agent: etanercept)
  • Prednisolon (Dosages: 5mg, active agent: glucocorticoid)
Parameter Result Ref. / Cut-Off Measuring Information
Anti-cyclic citrullinated Peptide (CCP) / anti-citrullinated Protein Antibodies (ACPA)
Qual:
Quant: 294.5 IU/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH295851
1 mL (€37.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-cyclic citrullinated Peptide (CC... - M06.99

Donor:
Gender: Female Age: 37
Diagnosed disease:
M06.99
Medication:
Prednisolon
Parameter:
Anti-cyclic citrullinated Peptide (CCP) / anti-citrullinated Protein Antibodies (ACPA)
Donor:
Gender:
Female
Age:
37 Years
BMI:
24 kg/m²
Weight:
69 kg
Height:
169 cm
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • M06.99
Medication:
  • Prednisolon (Dosages: 5mg, active agent: glucocorticoid)
  • RoActemra (Dosages: 162not specified, active agent: tocilizumab)
Parameter Result Ref. / Cut-Off Measuring Information
Anti-cyclic citrullinated Peptide (CCP) / anti-citrullinated Protein Antibodies (ACPA)
Qual:
Quant: 614.4 IU/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH295856
1 mL (€37.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-cyclic citrullinated Peptide (CC... - M05.00

Donor:
Gender: Female Age: 59
Diagnosed disease:
M05.00 - Felty syndrome
Medication:
Metex
Parameter:
Anti-cyclic citrullinated Peptide (CCP) / anti-citrullinated Protein Antibodies (ACPA)
Donor:
Gender:
Female
Age:
59 Years
BMI:
30 kg/m²
Weight:
77 kg
Height:
160 cm
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Felty syndrome [M05.00]
Medication:
  • Metex (Dosages: 7.5not specified)
  • leflunomide
Parameter Result Ref. / Cut-Off Measuring Information
Anti-cyclic citrullinated Peptide (CCP) / anti-citrullinated Protein Antibodies (ACPA)
Qual:
Quant: 796.2 IU/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH295849
1 mL (€37.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-cyclic citrullinated Peptide (CC... - M05.80

Donor:
Gender: Female Age: 53
Diagnosed disease:
M05.80
Medication:
Quensyl
Parameter:
Anti-cyclic citrullinated Peptide (CCP) / anti-citrullinated Protein Antibodies (ACPA)
Donor:
Gender:
Female
Age:
53 Years
BMI:
24 kg/m²
Weight:
72 kg
Height:
172 cm
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • M05.80
Medication:
  • Quensyl (active agent: hydroxychloroquine)
  • methotrexate (Dosages: 10mg)
Parameter Result Ref. / Cut-Off Measuring Information
Anti-cyclic citrullinated Peptide (CCP) / anti-citrullinated Protein Antibodies (ACPA)
Qual: positive
Quant: > 500 IU/mL
Source: previous donation
not specified not specified
Method: not specified
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH295850
1 mL (€37.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Thyroid peroxidase (aTPO / MAK)

Donor:
Gender: Female Age: 52
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 p24 (HIV-1/2 p24) Anti-Thyroglobulin (aTg / TAK) Anti-Thyroid peroxidase (aTPO / MAK) Hepatitis B Virus surface Antigen (HBsAg)
Donor:
Gender:
Female
Age:
52 Years
BMI:
27.1 kg/m²
Weight:
82 kg
Height:
174 cm
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • autoimmune thyroiditis
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual: negative
Quant:
Source: this donation
negative
Method: not specified
System: DXi Beckman Coulter
Anti-Human Immunodeficiency Virus-1/2 p24 (HIV-1/2 p24)
Qual: negative
Quant:
Source: this donation
negative
Method: not specified
System: DXi Beckman Coulter
Anti-Thyroglobulin (aTg / TAK)
Qual: negative
Quant: < 20 kU/L
Source: previous donation
< 40 kU/L
Method: CLIA (Chemiluminescence Immuno Assay)
System: Immulite Siemens
Anti-Thyroglobulin (aTg / TAK)
Qual: negative
Quant: < 20 kU/L
Source: this donation
< 40 kU/L
Method: not specified
System: not specified not specified
Anti-Thyroid peroxidase (aTPO / MAK)
Qual: positive
Quant: 732.00 kU/L
Source: this donation
Remarks: dilution 1:10
< 35 kU/L
Method: not specified
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual: negative
Quant:
Source: this donation
negative
Method: not specified
System: DXi Beckman Coulter
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH140026
1 mL (€37.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Thyroglobulin (aTg / TAK), Anti-...

Donor:
Gender: Female Age: 39
Parameter:
Anti-Thyroglobulin (aTg / TAK) Anti-Thyroid peroxidase (aTPO / MAK) Thyrotropin (TSH) Thyroxine (FT4) Triiodothyronine (FT3)
Donor:
Gender:
Female
Age:
39 Years
BMI:
32 kg/m²
Weight:
83 kg
Height:
161 cm
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Graves disease
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Thyroglobulin (aTg / TAK)
Qual: positive
Quant: 84.50 kU/L
Source: this donation
< 40 kU/L
Method: not specified
System: not specified not specified
Anti-Thyroglobulin (aTg / TAK)
Qual: positive
Quant: 84.5 kU/L
Source: previous donation
< 40 kU/L
Method: CLIA (Chemiluminescence Immuno Assay)
System: Immulite Siemens
Anti-Thyroid peroxidase (aTPO / MAK)
Qual: positive
Quant: 2478.00 kU/L
Source: this donation
Remarks: dilution 1:10
< 35 kU/L
Method: not specified
System: not specified not specified
Anti-Thyroid peroxidase (aTPO / MAK)
Qual: positive
Quant: 2478 kU/L
Source: previous donation
< 35 kU/L
Method: CLIA (Chemiluminescence Immuno Assay)
System: Immulite Siemens
Thyrotropin (TSH)
Qual: negative
Quant: 1.5 mIU/L
Source: previous donation
0.27 - 4.2 mIU/L
Method: not specified
System: Cobas e 601 Roche
Thyroxine (FT4)
Qual: positive
Quant: 16.9 pmol/L
Source: previous donation
113 - 23 pmol/L
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Triiodothyronine (FT3)
Qual: negative
Quant: 3.4 pmol/L
Source: previous donation
2.8 - 7.1 pmol/L
Method: not specified
System: DXI Beckman Coulter
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH139713
1 mL (€37.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289119
233 mL (€8,737.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289079
241 mL (€9,037.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289020
243 mL (€9,112.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289025
245 mL (€9,187.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289026
247 mL (€9,262.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH288999
252 mL (€9,450.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289128
252 mL (€9,450.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289028
253 mL (€9,487.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289053
255 mL (€9,562.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289133
255 mL (€9,562.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289045
259 mL (€9,712.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289041
260 mL (€9,750.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289126
260 mL (€9,750.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289092
261 mL (€9,787.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289016
261 mL (€9,787.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289120
262 mL (€9,825.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289078
264 mL (€9,900.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289002
266 mL (€9,975.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289046
267 mL (€10,012.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289033
268 mL (€10,050.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289056
268 mL (€10,050.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289082
269 mL (€10,087.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human CPD plasma - Anti-Hepatitis C Virus (HCV), Anti-Hu... - Self-reported Healthy

Donor:
Gender: Not specified
Parameter:
Anti-Hepatitis C Virus (HCV) Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2) Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2) Hepatitis B Virus deoxyribonucleic acid (HBV-DNA) Hepatitis B Virus surface Antigen (HBsAg) Hepatitis C Virus deoxyribonucleic acid (HCV-DNA) Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA) Syphilis (Treponema pallidum)
Donor:
Gender:
Not specified
Age:
Years
Sample:
Matrix:
CPD plasma
Condition:
perfect
Stored at:
Kit Product Code: NB004, CE marked without CE number
Freeze-Thaw-Cycle:
0
Diseases:
  • Self-reported healthy
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Hepatitis C Virus (HCV)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 6A52-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human Immunodeficiency Virus-1/2 (HIV-1/2)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 7G46-48, CE 0123
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Anti-Human T-lymphotropic Virus-1/2 (HTLV-1/2)
Qual:
Quant: non reactive -
Source: this donation
negative -
Method: CLIA (Chemiluminescence Immuno Assay)
System: not specified not specified
Hepatitis B Virus deoxyribonucleic acid (HBV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Hepatitis B Virus surface Antigen (HBsAg)
Qual:
Quant: non reactive -
Source: this donation
Remarks: Kit Product Code: 2G22 , CE 0843
negative -
Method: CMIA (Chemiluminescence Micro Particle Immuno Assay)
System: not specified not specified
Hepatitis C Virus deoxyribonucleic acid (HCV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Human Immunodeficiency Virus deoxyribonucleic acid (HIV-DNA)
Qual: negative
Quant: -
Source: this donation
Remarks: Kit Product Code: 480 test cassette (P/N 06997716190), CE 0123
negative -
Method: PCR (Polymerase Chain Reaction)
System: not specified not specified
Syphilis (Treponema pallidum)
Qual: < -18 degrees Celsius
Quant: non reactive
Source: -
Remarks: NewBio
negative -
Remarks: this donation
Method: TPHA (Treponema pallidum haemagglutination assay)
System: not specified not specified
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH289047
270 mL (€10,125.00)
Will be delivered in 16 to 20 Business Days (€180.00)
  • <
  • 1