Arthropathy Samples

Central BioHub offers Arthropathy Samples which comprise human serum specimens with the following laboratory parameters: Capsule-reactive protein, Complement C3, Complement C4, Rheumatoid Factor IgA as well as Rheumatoid Factor IgG. You can use our filter functions to refine your search, for example for a certain disease. For normal control groups please switch to the category Healthy Donors. If you do not find the research samples you are looking for, please contact us.

Available filters
-
-
13,994 Products

Human Serum - Antinuclear Antibodies (ANA) - L40.5

Donor:
Gender: Male Age: 63
Diagnosed disease:
M07
Medication:
Enbrel
Parameter:
Anti-Centromere Protein B (CENP-B) Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Ku Anti-Mi-2 Anti-Nucleosome Anti-OJ Protein Anti-PL-12 Anti-PL-7 Anti-PM-Scl-100 ...
Donor:
Gender:
Male
Age:
63 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Arthropathic psoriasis (M07.0-M07.3, M09.0) [L40.5]
  • M07
Medication:
  • Enbrel
  • Humira
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Ku
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Mi-2
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-OJ Protein
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PL-12
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PL-7
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl-100
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl-75
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant: 1.70 U/mL
Source: this donation
< 25.00 U/mL
Remarks: 15,00 - 25,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant: 0.40 U/mL
Source: this donation
< 25.00 U/mL
Remarks: 15,00 - 25,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Signal recognition particle (SRP)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant: 0.6 U/mL
Source: this donation
< 25.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-U1 small nuclear ribonucleoprotein (U1-snRNP)
Qual: negative
Quant: 1 U/mL
Source: this donation
< 25.00 U/mL
Remarks: 15,00 - 25,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antinuclear Antibodies (ANA)
Qual:
Quant: 0.263888889 Titer
Source: this donation
Remarks: fg Chr PL fg
negative Titer
Method: IIFT (Indirect Immunfluorescence Test)
System: IFSprinter EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual: negative
Quant: 2.90 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual: negative
Quant: 1.31 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual: negative
Quant: 0.21 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
EJ-Protein
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Rheumatoid Factor (RF) IgA
Qual: negative
Quant: 5.2 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual: negative
Quant: 4.1 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual: negative
Quant: < 1.00 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH214269
0.4 mL (€45.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-double-stranded DNA (dsDNA), Cap... - L40.5

Donor:
Gender: Female Age: 61
Diagnosed disease:
M07.0/1/2/3
Medication:
Enbrel
Parameter:
Anti-Centromere Protein B (CENP-B) Anti-Gliadin IgG Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) ...
Donor:
Gender:
Female
Age:
61 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Arthropathic psoriasis (M07.0-M07.3, M09.0) [L40.5]
  • M07.0/1/2/3
Medication:
  • Enbrel
  • Humira
  • Prolia
  • Remicade
  • Simponi
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Gliadin IgG
Qual: negative
Quant: 4.18 RU/mL
Source: this donation
< 25.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Thyroglobulin (aTg / TAK)
Qual: negative
Quant: 20 IU/mL
Source: this donation
< 100 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Thyroid peroxidase (aTPO / MAK)
Qual: negative
Quant: 10 IU/mL
Source: this donation
< 50.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Tissue transglutaminase (tTG) IgA
Qual: negative
Quant: 2 RU/mL
Source: this donation
< 20.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: positive
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual: positive
Quant: 43.1 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual: negative
Quant: 1.19 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual: negative
Quant: 0.19 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Rheumatoid Factor (RF) IgA
Qual: negative
Quant: 3.2 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual: negative
Quant: 5.5 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual: negative
Quant: < 1.00 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
TSH Receptor Antibodies (TRAb)
Qual: negative
Quant: 0.56 IU/L
Source: this donation
< 1.80 IU/L
Remarks: 1,80 - 2,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH215845
0.8 mL (€90.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-PM-Scl-75, Antinuclear Antibodie... - M06.0

Donor:
Gender: Female Age: 24
Diagnosed disease:
M06.0 - Seronegative rheumatoid arthritis
Medication:
Cimzia
Parameter:
Anti-Centromere Protein B (CENP-B) Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Ku Anti-Mi-2 Anti-Nucleosome Anti-OJ Protein Anti-PL-12 Anti-PL-7 Anti-PM-Scl-100 ...
Donor:
Gender:
Female
Age:
24 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Seronegative rheumatoid arthritis [M06.0]
Medication:
  • Cimzia
  • Enbrel
  • Humira
  • Otezla
  • RoActemra
  • Stelara
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Ku
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Mi-2
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-OJ Protein
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PL-12
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PL-7
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl-100
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl-75
Qual: positive
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Signal recognition particle (SRP)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antinuclear Antibodies (ANA)
Qual:
Quant: not specified Titer
Source: this donation
Remarks: subsequent claim possible
negative Titer
Method: IIFT (Indirect Immunfluorescence Test)
System: iPro ORGENTEC Diagnostika GmbH
Capsule-reactive protein (CRP)
Qual: positive
Quant: 5.65 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual: negative
Quant: 1.64 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual: negative
Quant: 0.33 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
EJ-Protein
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Rheumatoid Factor (RF) IgA
Qual: negative
Quant: < 1.00 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual: negative
Quant: 6.6 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual: negative
Quant: < 1.00 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH217092
0.6 mL (€67.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Antinuclear Antibodies (ANA), Capsule... - M05.8

Donor:
Gender: Female Age: 64
Diagnosed disease:
M05.8 - Other seropositive rheumatoid arthritis
Medication:
Cimzia
Parameter:
Anti-Bactericidal / Permeability Increasing Protein (BPI) Anti-Centromere Protein B (CENP-B) Anti-Gliadin IgG Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Myeloperoxidase (MPO) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-Proteinase 3 (PR3) ...
Donor:
Gender:
Female
Age:
64 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Other seropositive rheumatoid arthritis [M05.8]
Medication:
  • Cimzia
  • Enbrel
  • Humira
  • MabThera
  • Orencia
  • RoActemra
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Bactericidal / Permeability Increasing Protein (BPI)
Qual: negative
Quant: 5.00 U/mL
Source: this donation
< 10 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-Centromere Protein B (CENP-B)
Qual:
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Gliadin IgG
Qual: negative
Quant: 2.00 RU/mL
Source: this donation
< 25 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Histone
Qual:
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual:
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Myeloperoxidase (MPO)
Qual: negative
Quant: 1.70 U/mL
Source: this donation
< 5 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-Nucleosome
Qual:
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual:
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual:
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proteinase 3 (PR3)
Qual: negative
Quant: 3.50 U/mL
Source: this donation
< 10 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-RNP/Sm
Qual:
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual:
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual:
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual:
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual:
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Thyroglobulin (aTg / TAK)
Qual: negative
Quant: 20.00 IU/mL
Source: this donation
< 100 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Thyroid peroxidase (aTPO / MAK)
Qual: negative
Quant: 10.00 IU/mL
Source: this donation
< 50 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Tissue transglutaminase (tTG) IgA
Qual: negative
Quant: 2.00 RU/mL
Source: this donation
< 20 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant: 6.20 IU/mL
Source: this donation
< 20 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-ribosomal P-Protein (ARPA)
Qual:
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual:
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antinuclear Antibodies (ANA)
Qual:
Quant: 0.486111111 Titer
Source: this donation
Remarks: fghg Chr PL fg
negative Titer
Method: IIFT (Indirect Immunfluorescence Test)
System: IFSprinter EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual: positive
Quant: 20.80 mg/L
Source: this donation
0 - 3 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual: negative
Quant: 1.30 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual: negative
Quant: 0.23 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Rheumatoid Factor (RF) IgA
Qual: positive
Quant: > 500.00 U/mL
Source: this donation
< 20 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual: positive
Quant: > 500.00 U/mL
Source: this donation
< 20 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual: positive
Quant: > 500.00 IU/mL
Source: this donation
< 20 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH191334
0.6 mL (€67.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-Neutrophil Cytoplasmic Antibodie... - D69.6-

Donor:
Gender: Female Age: 68
Diagnosed disease:
M17.9 - Gonarthrosis, unspecified
Medication:
Enbrel
Parameter:
25-Hydroxy-Vitamin D3 (Calcidiol) Anti-Bone-specific Alkaline Phosphatase (BAP) Anti-Centromere Protein B (CENP-B) Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Myeloperoxidase (MPO) Anti-Neutrophil Cytoplasmic Antibodies (ANCA) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) ...
Donor:
Gender:
Female
Age:
68 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • D69.6-
  • I10.90
  • Primary biliary cirrhosis [K74.3]
  • Other specified inflammatory liver diseases [K75.8]
  • Arthropathic psoriasis (M07.0-M07.3, M09.0) [L40.5]
  • M05.9-
  • M06.99
  • M06
  • M07.-
  • Gonarthrosis, unspecified [M17.9]
Medication:
  • Enbrel
  • MabThera
Parameter Result Ref. / Cut-Off Measuring Information
25-Hydroxy-Vitamin D3 (Calcidiol)
Qual: negative
Quant: 36.70 ng/mL
Source: this donation
30.00 - 100 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Anti-Bone-specific Alkaline Phosphatase (BAP)
Qual: negative
Quant: 25.40 µg/L
Source: this donation
5.50 - 27.10 µg/L
Remarks: sex and age dependant
Method: EIA (Enzyme Immuno Assay)
System: ISYS IDS
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Myeloperoxidase (MPO)
Qual: negative
Quant: 0.80 U/mL
Source: this donation
< 5.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-Neutrophil Cytoplasmic Antibodies (ANCA)
Qual:
Quant: not specified Titer
Source: this donation
Remarks: subsequent claim possible
negative Titer
Method: IIFT (Indirect Immunfluorescence Test)
System: iPro EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proteinase 3 (PR3)
Qual: negative
Quant: 2.70 U/mL
Source: this donation
< 10.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: positive
Quant: +++
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antinuclear Antibodies (ANA)
Qual:
Quant: not specified Titer
Source: this donation
Remarks: subsequent claim possible
negative Titer
Method: IIFT (Indirect Immunfluorescence Test)
System: iPro ORGENTEC Diagnostika GmbH
Capsule-reactive protein (CRP)
Qual: positive
Quant: 16.50 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual: negative
Quant: 1.25 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual: negative
Quant: 0.27 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Osteocalcin
Qual: negative
Quant: 16.40 ng/mL
Source: this donation
10.40 - 45.60 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Parathyroid hormone (PTH)
Qual: negative
Quant: 14.00 pg/mL
Source: this donation
11.50 - 78.40 pg/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Rheumatoid Factor (RF) IgA
Qual: positive
Quant: 350.80 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual: positive
Quant: > 500 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual: positive
Quant: > 500 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Serum Crosslaps
Qual: negative
Quant: 0.38 ng/mL
Source: this donation
0.14 - 1.35 ng/mL
Remarks: sex and age dependant
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH286062
0.9 mL (€101.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Beta-CrossLaps (b-CTX), Osteocalcin, ... - M05.80

Donor:
Gender: Male Age: 58
Diagnosed disease:
M05.80
Medication:
Cimzia
Parameter:
25-Hydroxy-Vitamin D3 (Calcidiol) Anti-Centromere Protein B (CENP-B) Anti-Gliadin IgG Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) ...
Donor:
Gender:
Male
Age:
58 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • M05.80
Medication:
  • Cimzia
  • Enbrel
  • MabThera
  • Roactemra
  • Simponi
Parameter Result Ref. / Cut-Off Measuring Information
25-Hydroxy-Vitamin D3 (Calcidiol)
Qual: negative
Quant: 33.90 ng/mL
Source: this donation
30.00 - 100 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Gliadin IgG
Qual: negative
Quant: 2.00 RU/mL
Source: this donation
< 25.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Histone
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Beta-CrossLaps (b-CTX)
Qual: positive
Quant: 0.038 ng/mL
Source: this donation
0.115 - 0.748 ng/mL
Remarks: sex and age dependent
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Bone alkaline phosphatase (BAP)
Qual: negative
Quant: 12.10 µg/L
Source: this donation
5.70 - 32.90 µg/L
Remarks: sex and age dependent
Method: EIA (Enzyme Immuno Assay)
System: ISYS IDS
Capsule-reactive protein (CRP)
Qual: negative
Quant: 1.09 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual: negative
Quant: 1.10 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual: negative
Quant: 0.19 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Osteocalcin
Qual: positive
Quant: 5.90 ng/mL
Source: this donation
10.40 - 45.60 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Parathyroid hormone (PTH)
Qual: negative
Quant: 55.30 pg/mL
Source: this donation
11.50 - 78.40 pg/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Rheumatoid Factor (RF) IgA
Qual: positive
Quant: 61.40 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual: positive
Quant: 192.40 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual: positive
Quant: 485.80 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH222856
1.1 mL (€123.75)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - 25-Hydroxy-Vitamin D3 (Calcidiol), Ca... - A68.9

Donor:
Gender: Female Age: 50
Diagnosed disease:
M09.0-*
Medication:
Enbrel
Parameter:
25-Hydroxy-Vitamin D3 (Calcidiol) Anti-Centromere Protein B (CENP-B) Anti-Gliadin IgG Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) ...
Donor:
Gender:
Female
Age:
50 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Relapsing fever, unspecified [A68.9]
  • Iodine-deficiency-related multinodular (endemic) goitre [E01.1]
  • Vitamin D deficiency, unspecified [E55.9]
  • Postviral fatigue syndrome [G93.3]
  • Arthropathic psoriasis (M07.0-M07.3, M09.0) [L40.5]
  • M06.90
  • M07.0/1/2/3
  • M07.39*
  • M09.0-*
Medication:
  • Enbrel
  • Humira
  • Stelara
Parameter Result Ref. / Cut-Off Measuring Information
25-Hydroxy-Vitamin D3 (Calcidiol)
Qual: positive
Quant: 25.60 ng/mL
Source: this donation
30.00 - 100 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Gliadin IgG
Qual: negative
Quant: 11.78 RU/mL
Source: this donation
< 25.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Tissue transglutaminase (tTG) IgA
Qual: negative
Quant: 2.00 RU/mL
Source: this donation
< 20.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Bone alkaline phosphatase (BAP)
Qual: negative
Quant: 19.50 µg/L
Source: this donation
4.70 - 27.00 µg/L
Remarks: sex and age dependent
Method: EIA (Enzyme Immuno Assay)
System: ISYS IDS
Capsule-reactive protein (CRP)
Qual: positive
Quant: 8.37 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual: negative
Quant: 1.68 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual: negative
Quant: 0.40 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Osteocalcin
Qual: positive
Quant: 4.70 ng/mL
Source: this donation
10.40 - 45.60 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Parathyroid hormone (PTH)
Qual: negative
Quant: 26.00 pg/mL
Source: this donation
11.50 - 78.40 pg/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Rheumatoid Factor (RF) IgA
Qual: negative
Quant: 6.00 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual: negative
Quant: 8.60 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual: negative
Quant: 2.50 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Serum Crosslaps
Qual: negative
Quant: < 0.03 ng/mL
Source: this donation
0.11 - 0.74 ng/mL
Remarks: sex and age dependent
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH71612
0.3 mL (€33.75)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - 25-Hydroxy-Vitamin D3 (Calcidiol), An... - E55.9

Donor:
Gender: Male Age: 55
Diagnosed disease:
M06.99
Medication:
Cimzia
Parameter:
25-Hydroxy-Vitamin D3 (Calcidiol) Anti-Bactericidal / Permeability Increasing Protein (BPI) Anti-Mutated citrullinated Vimentin (MCV) Anti-Myeloperoxidase (MPO) Anti-Nucleosome Anti-Proteinase 3 (PR3) Anti-cyclic citrullinated Peptide (CCP) / anti-citrullinated Protein Antibodies (ACPA) Anti-double-stranded DNA (dsDNA) Beta-CrossLaps (b-CTX) Bone alkaline phosphatase (BAP) ...
Donor:
Gender:
Male
Age:
55 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Vitamin D deficiency, unspecified [E55.9]
  • Hyperuricaemia without signs of inflammatory arthritis and tophaceous disease [E79.0]
  • M05.-
  • M05.30
  • M05.80
  • Other seropositive rheumatoid arthritis [M05.8]
  • M06.99
Medication:
  • Cimzia
  • Enbrel
  • Humira
  • Orencia (restart: 2009-07, 27.04.2010 , 2010-09)
  • RoActemra
Parameter Result Ref. / Cut-Off Measuring Information
25-Hydroxy-Vitamin D3 (Calcidiol)
Qual: positive
Quant: 23.10 ng/mL
Source: this donation
30 - 100 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Anti-Bactericidal / Permeability Increasing Protein (BPI)
Qual: negative
Quant: 4.40 U/mL
Source: this donation
< 10 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-Mutated citrullinated Vimentin (MCV)
Qual: positive
Quant: > 1000.00 U/mL
Source: this donation
< 20 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-Myeloperoxidase (MPO)
Qual: negative
Quant: 0.70 U/mL
Source: this donation
< 5 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-Nucleosome
Qual: negative
Quant: 18.00 U/mL
Source: this donation
< 20 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-Proteinase 3 (PR3)
Qual: negative
Quant: 1.90 U/mL
Source: this donation
<10 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-cyclic citrullinated Peptide (CCP) / anti-citrullinated Protein Antibodies (ACPA)
Qual: positive
Quant: > 200.00 RU/mL
Source: this donation
< 5 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant: 5.90 IU/mL
Source: this donation
< 20 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Beta-CrossLaps (b-CTX)
Qual: negative
Quant: 0.202 ng/mL
Source: this donation
0.115 - 0.748 ng/mL
Remarks: sex and age dependent
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Bone alkaline phosphatase (BAP)
Qual: negative
Quant: 14.70 µg/L
Source: this donation
5.70 - 32.90 µg/L
Remarks: sex and age dependent
Method: EIA (Enzyme Immuno Assay)
System: ISYS IDS
Capsule-reactive protein (CRP)
Qual: positive
Quant: 28.10 mg/L
Source: this donation
0 - 3 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual: negative
Quant: 1.55 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual: negative
Quant: 0.29 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Osteocalcin
Qual: negative
Quant: 11.60 ng/mL
Source: this donation
10.40 - 45.60 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Parathyroid hormone (PTH)
Qual: negative
Quant: 27.00 pg/mL
Source: this donation
11.50 - 78.40 pg/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Rheumatoid Factor (RF) IgA
Qual: positive
Quant: 226.10 U/mL
Source: this donation
< 20 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual: positive
Quant: > 500.00 U/mL
Source: this donation
< 20 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual: positive
Quant: > 500.00 IU/mL
Source: this donation
< 20 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH218086
0.4 mL (€45.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-SS-A 52 kDa (Ro 52), Rheumatoid ... - E55.9

Donor:
Gender: Male Age: 56
Diagnosed disease:
M06.99
Medication:
Cimzia
Parameter:
Anti-Centromere Protein B (CENP-B) Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) Anti-SS-B (La) ...
Donor:
Gender:
Male
Age:
56 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Vitamin D deficiency, unspecified [E55.9]
  • Hyperuricaemia without signs of inflammatory arthritis and tophaceous disease [E79.0]
  • M05.-
  • M05.30
  • M05.8-
  • M05.80
  • M06.99
Medication:
  • Cimzia
  • Enbrel
  • Humira
  • Orencia (restart: 2009-07, restart: 27.04.2010, restart: 2010-09)
  • RoActemra
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Histone
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: positive
Quant: (+) -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual: negative
Quant: 2.89 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual: negative
Quant: 1.33 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual: negative
Quant: 0.23 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Rheumatoid Factor (RF) IgA
Qual: positive
Quant: 191.30 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual: positive
Quant: 368.40 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual: positive
Quant: 496.40 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH218441
0.7 mL (€78.75)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-SS-A (Ro 52 and Ro 60), Anti-SS-... - I10.90

Donor:
Gender: Female Age: 80
Diagnosed disease:
M17.9 - Gonarthrosis, unspecified
Medication:
Enbrel
Parameter:
Anti-Bactericidal / Permeability Increasing Protein (BPI) Anti-Centromere Protein B (CENP-B) Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro 52 and Ro 60) Anti-SS-A 52 kDa (Ro 52) ...
Donor:
Gender:
Female
Age:
80 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • I10.90
  • M06.90
  • Polyarthrosis, unspecified [M15.9]
  • M16,0
  • Gonarthrosis, unspecified [M17.9]
Medication:
  • Enbrel
  • Orencia
  • Simponi
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Bactericidal / Permeability Increasing Protein (BPI)
Qual: negative
Quant: 4.10 U/mL
Source: this donation
< 10 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro 52 and Ro 60)
Qual: positive
Quant: +++
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro 52 and Ro 60)
Qual: positive
Quant: > 200.00 U/mL
Source: this donation
< 15 U/mL
Remarks: borderline: 15 - 25
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-SS-A 52 kDa (Ro 52)
Qual: positive
Quant: +++
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant: 5.80 U/mL
Source: this donation
< 15 U/mL
Remarks: borderline: 15 - 25
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant: 0.80 U/mL
Source: this donation
<15 U/mL
Remarks: borderline: 15 - 25
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-U1 small nuclear ribonucleoprotein 70 kDa (U1-snRNP)
Qual: negative
Quant: 0.90 U/mL
Source: this donation
< 25 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antinuclear Antibodies (ANA)
Qual:
Quant: 0.263888889 Titer
Source: this donation
Remarks: fg Chr VD AMA
negative Titer
Method: IIFT (Indirect Immunfluorescence Test)
System: IFSprinter EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual: positive
Quant: 8.76 mg/L
Source: this donation
0 - 3 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual: negative
Quant: 1.17 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual: negative
Quant: 0.14 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Rheumatoid Factor (RF) IgA
Qual: negative
Quant: 11.10 U/mL
Source: this donation
< 20 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual: negative
Quant: 11.10 U/mL
Source: this donation
< 20 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual: negative
Quant: 8.30 IU/mL
Source: this donation
< 20 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH218975
0.8 mL (€90.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Capsule-reactive protein (CRP) - I80.20

Donor:
Gender: Female Age: 38
Diagnosed disease:
M09.0-*
Medication:
Cimzia
Parameter:
25-Hydroxy-Vitamin D3 (Calcidiol) Anti-Centromere Protein B (CENP-B) Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) ...
Donor:
Gender:
Female
Age:
38 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • I80.20
  • Arthropathic psoriasis (M07.0-M07.3, M09.0) [L40.5]
  • Seronegative rheumatoid arthritis [M06.0]
  • M07.0/1/2/3*
  • M08.90
  • M09.0-*
Medication:
  • Cimzia
  • Cosentyx
  • Enbrel
  • Humira
  • MabThera
  • Orencia
  • RoActemra
  • Stelara
Parameter Result Ref. / Cut-Off Measuring Information
25-Hydroxy-Vitamin D3 (Calcidiol)
Qual: negative
Quant: 36.90 ng/mL
Source: this donation
30.00 - 100 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Histone
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Beta-CrossLaps (b-CTX)
Qual: negative
Quant: 0.230 ng/mL
Source: this donation
0.112 - 0.738 ng/mL
Remarks: sex and age dependent
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Bone alkaline phosphatase (BAP)
Qual: negative
Quant: 14.00 µg/L
Source: this donation
4.70 - 27.00 µg/L
Remarks: sex and age dependent
Method: EIA (Enzyme Immuno Assay)
System: ISYS IDS
Capsule-reactive protein (CRP)
Qual: positive
Quant: 13.00 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual: negative
Quant: 1.09 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual: negative
Quant: 0.23 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Osteocalcin
Qual: negative
Quant: 19.20 ng/mL
Source: this donation
10.40 - 45.60 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Parathyroid hormone (PTH)
Qual: negative
Quant: 39.60 pg/mL
Source: this donation
11.50 - 78.40 pg/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Rheumatoid Factor (RF) IgA
Qual: negative
Quant: 8.80 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual: negative
Quant: 12.20 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual: negative
Quant: 19.00 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH213262
0.8 mL (€90.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-double-stranded DNA (dsDNA), Cap... - I10.90

Donor:
Gender: Female Age: 52
Diagnosed disease:
M15.9 - Polyarthrosis, unspecified
Medication:
Cimzia
Parameter:
Anti-Centromere Protein B (CENP-B) Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) Anti-SS-B (La) ...
Donor:
Gender:
Female
Age:
52 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • I10.90
  • Arthropathic psoriasis (M07.0-M07.3, M09.0) [L40.5]
  • Seronegative rheumatoid arthritis [M06.0]
  • M06.99
  • M07.0/1/2/3*
  • M09.0-*
  • Polyarthrosis, unspecified [M15.9]
Medication:
  • Cimzia
  • Cosentyx
  • Enbrel
  • Humira
  • RoActemra
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Histone
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: positive
Quant: (+) -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual: positive
Quant: 7.01 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual: negative
Quant: 1.42 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual: negative
Quant: 0.33 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH213477
0.8 mL (€90.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Capsule-reactive protein (CRP) - E14.9

Donor:
Gender: Male Age: 71
Diagnosed disease:
M09.0 - Juvenile arthritis in psoriasis (L40.5)
Medication:
Enbrel
Parameter:
25-Hydroxy-Vitamin D3 (Calcidiol) Anti-Bone-specific Alkaline Phosphatase (BAP) Anti-Centromere Protein B (CENP-B) Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) ...
Donor:
Gender:
Male
Age:
71 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Unspecified diabetes mellitus without complications [E14.9]
  • Vitamin D deficiency, unspecified [E55.9]
  • Arthropathic psoriasis (M07.0-M07.3, M09.0) [L40.5]
  • M06.90
  • M07.0/1/2/3
  • Juvenile arthritis in psoriasis (L40.5) [M09.0]
Medication:
  • Enbrel
  • Humira
  • Orencia
Parameter Result Ref. / Cut-Off Measuring Information
25-Hydroxy-Vitamin D3 (Calcidiol)
Qual: negative
Quant: 31.30 ng/mL
Source: this donation
30.00 - 100 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Anti-Bone-specific Alkaline Phosphatase (BAP)
Qual: negative
Quant: 24.90 µg/L
Source: this donation
5.70 - 32.90 µg/L
Remarks: sex and age dependent
Method: EIA (Enzyme Immuno Assay)
System: ISYS IDS
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual: positive
Quant: 109.00 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual: negative
Quant: 1.55 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual: negative
Quant: 0.28 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Osteocalcin
Qual: negative
Quant: 12.50 ng/mL
Source: this donation
10.40 - 45.60 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Parathyroid hormone (PTH)
Qual: negative
Quant: 53.10 pg/mL
Source: this donation
11.50 - 78.40 pg/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Rheumatoid Factor (RF) IgA
Qual: negative
Quant: 10.20 U/mL
Source: this donation
< 20 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual: negative
Quant: 8.70 U/mL
Source: this donation
< 20 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual: negative
Quant: < 1 IU/mL
Source: this donation
< 20 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Serum Crosslaps
Qual: negative
Quant: 0.13 ng/mL
Source: this donation
0.12 - 0.75 ng/mL
Remarks: sex and age dependent
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH72078
1.1 mL (€123.75)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-SS-A (Ro), Antinuclear Antibodie... - L40.5

Donor:
Gender: Female Age: 58
Diagnosed disease:
M07
Medication:
Cosentyx
Parameter:
Anti-Centromere Protein B (CENP-B) Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) Anti-SS-B (La) ...
Donor:
Gender:
Female
Age:
58 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Arthropathic psoriasis (M07.0-M07.3, M09.0) [L40.5]
  • M06
  • M07
Medication:
  • Cosentyx
  • Enbrel
  • Humira
  • Simponi
  • Stelara
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual:
Quant: low positive
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antinuclear Antibodies (ANA)
Qual:
Quant: 0.152777778 Titer
Source: this donation
Remarks: fg Chr
negative Titer
Method: IIFT (Indirect Immunfluorescence Test)
System: iPro ORGENTEC Diagnostika GmbH
Capsule-reactive protein (CRP)
Qual: negative
Quant: 2.67 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual: negative
Quant: 1.14 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual: negative
Quant: 0.32 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Rheumatoid Factor (RF) IgA
Qual: negative
Quant: 9.00 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual: negative
Quant: 7.40 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual: negative
Quant: 6.60 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH216454
0.3 mL (€33.75)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-Thyroid peroxidase (aTPO / MAK),... - L40

Donor:
Gender: Female Age: 77
Diagnosed disease:
M07
Medication:
Enbrel
Parameter:
Anti-Centromere Protein B (CENP-B) Anti-Gliadin IgG Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) Anti-SS-A 52 kDa (Ro 52) ...
Donor:
Gender:
Female
Age:
77 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • L40
  • M07
Medication:
  • Enbrel
  • Humira
  • Stelara
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Gliadin IgG
Qual: negative
Quant: 2.00 RU/mL
Source: this donation
< 25.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Thyroglobulin (aTg / TAK)
Qual: negative
Quant: 20.00 IU/mL
Source: this donation
< 100 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Thyroid peroxidase (aTPO / MAK)
Qual: positive
Quant: 10.00 IU/mL
Source: this donation
< 5.000 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-Tissue transglutaminase (tTG) IgA
Qual: negative
Quant: 2.00 RU/mL
Source: this donation
< 20.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: positive
Quant: +
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual: positive
Quant: 13.60 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual: negative
Quant: 1.60 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual: positive
Quant: 0.41 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Rheumatoid Factor (RF) IgA
Qual: negative
Quant: 5.80 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual: negative
Quant: 10.20 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual: negative
Quant: 4.00 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
TSH Receptor Antibodies (TRAb)
Qual: negative
Quant: 0.37 IU/L
Source: this donation
< 1.80 IU/L
Remarks: 1,80 - 2,00 borderline
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH218880
0.3 mL (€33.75)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Capsule-reactive protein (CRP), Osteo... - K50.9

Donor:
Gender: Female Age: 42
Diagnosed disease:
M06.99
Medication:
Enbrel
Parameter:
25-Hydroxy-Vitamin D3 (Calcidiol) Anti-Bone-specific Alkaline Phosphatase (BAP) Anti-Centromere Protein B (CENP-B) Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm Anti-SS-A (Ro) ...
Donor:
Gender:
Female
Age:
42 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Crohn disease, unspecified [K50.9]
  • M06.99
Medication:
  • Enbrel
  • Humira
  • Remicade
Parameter Result Ref. / Cut-Off Measuring Information
25-Hydroxy-Vitamin D3 (Calcidiol)
Qual: negative
Quant: 37 ng/mL
Source: this donation
30.00 - 100 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Anti-Bone-specific Alkaline Phosphatase (BAP)
Qual: negative
Quant: 6.2 µg/L
Source: this donation
4.70 - 27.00 µg/L
Remarks: sex and age dependent
Method: EIA (Enzyme Immuno Assay)
System: ISYS IDS
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Histone
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Nucleosome
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-RNP/Sm
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Smith (Sm)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant:
Source: this donation
negative
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual: positive
Quant: 5.64 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual: negative
Quant: 1.03 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual: negative
Quant: 0.22 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Osteocalcin
Qual: positive
Quant: 5.3 ng/mL
Source: this donation
10.40 - 45.60 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Parathyroid hormone (PTH)
Qual: negative
Quant: 16 pg/mL
Source: this donation
11.50 - 78.40 pg/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Rheumatoid Factor (RF) IgA
Qual: negative
Quant: < 1.00 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual: negative
Quant: 6.2 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual: negative
Quant: 3.1 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Serum Crosslaps
Qual: negative
Quant: < 0.03 ng/mL
Source: this donation
0.11 - 0.74 ng/mL
Remarks: sex and age dependent
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH215232
0.4 mL (€45.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - I10.90

Donor:
Gender: Female Age: 76
Diagnosed disease:
M05.80
Medication:
Enbrel
Parameter:
Anti-Bactericidal / Permeability Increasing Protein (BPI) Anti-Centromere Protein B (CENP-B) Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Ku Anti-Mi-2 Anti-Myeloperoxidase (MPO) Anti-Nucleosome Anti-OJ Protein Anti-PL-12 ...
Donor:
Gender:
Female
Age:
76 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • I10.90
  • M05.80
Medication:
  • Enbrel
  • Humira
  • Orencia
Parameter Result Ref. / Cut-Off Measuring Information
Anti-Bactericidal / Permeability Increasing Protein (BPI)
Qual: negative
Quant: 2.90 U/mL
Source: this donation
< 10.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-Centromere Protein B (CENP-B)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Histone
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Jo-1 (a-histidyl-tRNA synthetase)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Ku
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Mi-2
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Myeloperoxidase (MPO)
Qual: negative
Quant: 0.60 U/mL
Source: this donation
< 5.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-Nucleosome
Qual: negative
Quant: 9.00 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-OJ Protein
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PL-12
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PL-7
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl-100
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl-75
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-PM-Scl
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proliferating cell nuclear antigen (PCNA)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Proteinase 3 (PR3)
Qual: negative
Quant: 1.60 U/mL
Source: this donation
< 10.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-RNP/Sm
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A (Ro)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-A 52 kDa (Ro 52)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-SS-B (La)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Scl-70 (a-DNA topoisomerase I)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-Signal recognition particle (SRP)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual: negative
Quant: 2.60 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-ribosomal P-Protein (ARPA)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Antimitochondrial Antibodies (AMA-M2)
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Capsule-reactive protein (CRP)
Qual: negative
Quant: 1.42 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual: negative
Quant: 1.11 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual: negative
Quant: 0.24 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
EJ-Protein
Qual: negative
Quant: -
Source: this donation
negative -
Method: Immunoblot
System: EUROBlotMaster EUROIMMUN AG
Rheumatoid Factor (RF) IgA
Qual: negative
Quant: < 1.00 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual: negative
Quant: 10.70 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual: negative
Quant: 6.10 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Disclaimer
  • All products are intended for research or manufacturing purposes only. In particular, the direct application in humans or animals for therapeutic or diagnostic purposes is not permitted.
  • Molecular genetic tests that establish the donor's identity are prohibited.
  • Biospecimens should be treated as potentially infectious. Each specimen is to be used by qualified professionals only, who will safely handle and dispose of the products they receive.
  • An import permit for biological substances may be required, in which case it must be present for purchase.
CBH215798
0.4 mL (€45.00)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Anti-Neutrophil Cytoplasmic Antibodie... - M07

Donor:
Gender: Female Age: 66
Diagnosed disease:
M17
Medication:
Cosentyx
Parameter:
25-Hydroxy-Vitamin D3 (Calcidiol) Anti-Bone-specific Alkaline Phosphatase (BAP) Anti-Centromere Protein B (CENP-B) Anti-Histone Anti-Jo-1 (a-histidyl-tRNA synthetase) Anti-Neutrophil Cytoplasmic Antibodies (ANCA) Anti-Nucleosome Anti-PM-Scl Anti-Proliferating cell nuclear antigen (PCNA) Anti-RNP/Sm ...
Donor:
Gender:
Female
Age:
66 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • M07
  • M17
Medication:
  • Cosentyx
  • Enbrel
  • Humira
  • Remicade
  • Simponi
Parameter Result Ref. / Cut-Off Measuring Information
25-Hydroxy-Vitamin D3 (Calcidiol)
Qual: negative
Quant: 45.50 ng/mL
Source: this donation
30.00 - 100 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Anti-Bone-specific Alkaline Phosphatase (BAP)
Qual: negative
Quant: 19.60 µg/L
Source: this donation