Other Neoplasm Samples

The category Other Neoplasm Samples encompasses human serum samples which were measured for laboratory parameters like Cancer-Antigen 125, Cancer-Antigen 19-9, Prostate specific antigen, Lactate dehydrogenase or Carcino Embryonic Antigen. Please use our filter functions for your own customisation. For normal control groups please switch to the category Healthy Donors. If you do not find the research samples you are looking for, please contact us.

Available filters
-
243 Products

Human Serum - 25-Hydroxy-Vitamin D3 (Calcidiol), An... - D47.5

Donor:
Gender: Male Age: 30
Diagnosed disease:
D47.5 - Chronic eosinophilic leukaemia [hypereosinophilic syndrome]
Parameter:
25-Hydroxy-Vitamin D3 (Calcidiol) Anti-Bactericidal / Permeability Increasing Protein (BPI) Anti-Mutated citrullinated Vimentin (MCV) Anti-Myeloperoxidase (MPO) Anti-Proteinase 3 (PR3) Anti-cyclic citrullinated Peptide (CCP) / anti-citrullinated Protein Antibodies (ACPA) Anti-double-stranded DNA (dsDNA) Beta-CrossLaps (b-CTX) Bone alkaline phosphatase (BAP) Capsule-reactive protein (CRP) ...
Donor:
Gender:
Male
Age:
30 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Diseases:
  • Chronic eosinophilic leukaemia [hypereosinophilic syndrome] [D47.5]
Parameter Result Ref. / Cut-Off Measuring Information
25-Hydroxy-Vitamin D3 (Calcidiol)
Qual:
Quant: 44.60 ng/mL
Source: this donation
30.00 - 100 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Anti-Bactericidal / Permeability Increasing Protein (BPI)
Qual:
Quant: 5.70 U/mL
Source: this donation
< 10.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-Mutated citrullinated Vimentin (MCV)
Qual:
Quant: 9.40 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-Myeloperoxidase (MPO)
Qual:
Quant: 0.80 U/mL
Source: this donation
< 5.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-Proteinase 3 (PR3)
Qual:
Quant: 0.70 U/mL
Source: this donation
< 10.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Anti-cyclic citrullinated Peptide (CCP) / anti-citrullinated Protein Antibodies (ACPA)
Qual:
Quant: 3.02 RU/mL
Source: this donation
< 5.00 RU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: Analyzer1 EUROIMMUN AG
Anti-double-stranded DNA (dsDNA)
Qual:
Quant: 5.40 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Beta-CrossLaps (b-CTX)
Qual:
Quant: 0.259 ng/mL
Source: this donation
0.115 - 0.748 ng/mL
Remarks: sex and age dependent
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Bone alkaline phosphatase (BAP)
Qual:
Quant: 16.40 µg/L
Source: this donation
5.70 - 32.90 µg/L
Remarks: sex and age dependent
Method: EIA (Enzyme Immuno Assay)
System: ISYS IDS
Capsule-reactive protein (CRP)
Qual:
Quant: 1.11 mg/L
Source: this donation
0.00 - 3.00 mg/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C3
Qual:
Quant: 0.89 g/L
Source: this donation
0.90 - 1.80 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Complement C4
Qual:
Quant: 0.16 g/L
Source: this donation
0.10 - 0.40 g/L
Method: Nephelometry
System: BN ProSpec Siemens
Osteocalcin
Qual:
Quant: 17.20 ng/mL
Source: this donation
10.40 - 45.60 ng/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Parathyroid hormone (PTH)
Qual:
Quant: 18.30 pg/mL
Source: this donation
11.50 - 78.40 pg/mL
Method: CLIA (Chemiluminescence Immuno Assay)
System: ISYS IDS
Rheumatoid Factor (RF) IgA
Qual:
Quant: < 1.00 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgG
Qual:
Quant: 7.30 U/mL
Source: this donation
< 20.00 U/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Rheumatoid Factor (RF) IgM
Qual:
Quant: < 1.00 IU/mL
Source: this donation
< 20.00 IU/mL
Method: ELISA (Enzyme Linked Immunosorbent Assay)
System: BEP2000 Siemens
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH183931
0.5 mL (€56.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Prostate specific antigen (PSA), total - D40.0

Donor:
Gender: Male Age: 65
Diagnosed disease:
D40.0 - Neoplasm of uncertain or unknown behaviour of prostate
Parameter:
Prostate specific antigen (PSA), total
Donor:
Gender:
Male
Age:
65 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Neoplasm of uncertain or unknown behaviour of prostate [D40.0]
Parameter Result Ref. / Cut-Off Measuring Information
Prostate specific antigen (PSA), total
Qual:
Quant: 8.23 ng/mL
Source: this donation
< 4.4 ng/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH167269
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Prostate specific antigen (PSA), total - D40.0

Donor:
Gender: Male Age: 61
Diagnosed disease:
D40.0 - Neoplasm of uncertain or unknown behaviour of prostate
Parameter:
Prostate specific antigen (PSA), total
Donor:
Gender:
Male
Age:
61 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Neoplasm of uncertain or unknown behaviour of prostate [D40.0]
Parameter Result Ref. / Cut-Off Measuring Information
Prostate specific antigen (PSA), total
Qual:
Quant: 6.99 ng/mL
Source: this donation
< 4.4 ng/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH167289
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Cancer-Antigen 19-9 (CA 19-9) - C78.2

Donor:
Gender: Female Age: 61
Diagnosed disease:
C78.2 - Secondary malignant neoplasm of pleura
Parameter:
Cancer-Antigen 19-9 (CA 19-9)
Donor:
Gender:
Female
Age:
61 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Secondary malignant neoplasm of pleura [C78.2]
Parameter Result Ref. / Cut-Off Measuring Information
Cancer-Antigen 19-9 (CA 19-9)
Qual:
Quant: 41.40 U/mL
Source: this donation
< 39 U/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH167081
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Cancer-Antigen 125 (CA 125) - C78.6

Donor:
Gender: Female Age: 65
Diagnosed disease:
C78.6 - Secondary malignant neoplasm of retroperitoneum and peritoneum
Parameter:
Cancer-Antigen 125 (CA 125)
Donor:
Gender:
Female
Age:
65 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Secondary malignant neoplasm of retroperitoneum and peritoneum [C78.6]
Parameter Result Ref. / Cut-Off Measuring Information
Cancer-Antigen 125 (CA 125)
Qual:
Quant: 124.40 U/mL
Source: this donation
< 35 U/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH167146
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Prostate specific antigen (PSA), total - D40.0

Donor:
Gender: Male Age: 70
Diagnosed disease:
D40.0 - Neoplasm of uncertain or unknown behaviour of prostate
Parameter:
Prostate specific antigen (PSA), total
Donor:
Gender:
Male
Age:
70 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Neoplasm of uncertain or unknown behaviour of prostate [D40.0]
Parameter Result Ref. / Cut-Off Measuring Information
Prostate specific antigen (PSA), total
Qual:
Quant: 6.04 ng/mL
Source: this donation
< 4.4 ng/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH167262
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Carcino Embryonic Antigen (CEA) - D37.4

Donor:
Gender: Male Age: 92
Diagnosed disease:
D37.4 - Neoplasm of uncertain or unknown behaviour of colon
Parameter:
Carcino Embryonic Antigen (CEA)
Donor:
Gender:
Male
Age:
92 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Neoplasm of uncertain or unknown behaviour of colon [D37.4]
Parameter Result Ref. / Cut-Off Measuring Information
Carcino Embryonic Antigen (CEA)
Qual:
Quant: 2.40 ng/mL
Source: this donation
< 4.6 ng/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH172564
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Cancer-Antigen 125 (CA 125) - C77.5

Donor:
Gender: Female Age: 85
Diagnosed disease:
C77.5 - Secondary and unspecified malignant neoplasm of intrapelvic lymph nodes
Parameter:
Cancer-Antigen 125 (CA 125)
Donor:
Gender:
Female
Age:
85 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Secondary and unspecified malignant neoplasm of intrapelvic lymph nodes [C77.5]
Parameter Result Ref. / Cut-Off Measuring Information
Cancer-Antigen 125 (CA 125)
Qual:
Quant: 276.80 U/mL
Source: this donation
< 35 U/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH167148
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Cancer-Antigen 125 (CA 125) - C78.6

Donor:
Gender: Female Age: 65
Diagnosed disease:
C78.6 - Secondary malignant neoplasm of retroperitoneum and peritoneum
Parameter:
Cancer-Antigen 125 (CA 125)
Donor:
Gender:
Female
Age:
65 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Secondary malignant neoplasm of retroperitoneum and peritoneum [C78.6]
Parameter Result Ref. / Cut-Off Measuring Information
Cancer-Antigen 125 (CA 125)
Qual:
Quant: 173.40 U/mL
Source: this donation
< 35 U/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH167152
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Prostate specific antigen (PSA), total - D40.0

Donor:
Gender: Male Age: 66
Diagnosed disease:
D40.0 - Neoplasm of uncertain or unknown behaviour of prostate
Parameter:
Prostate specific antigen (PSA), total
Donor:
Gender:
Male
Age:
66 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Neoplasm of uncertain or unknown behaviour of prostate [D40.0]
Parameter Result Ref. / Cut-Off Measuring Information
Prostate specific antigen (PSA), total
Qual:
Quant: 9.09 ng/mL
Source: this donation
< 4.4 ng/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH167290
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Alpha-1-Fetoprotein (AFP) - D48.0

Donor:
Gender: Male Age: 36
Diagnosed disease:
D48.0 - Neoplasm of uncertain or unknown behaviour of bone and articular cartilage
Parameter:
Alpha-1-Fetoprotein (AFP)
Donor:
Gender:
Male
Age:
36 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Neoplasm of uncertain or unknown behaviour of bone and articular cartilage [D48.0]
Parameter Result Ref. / Cut-Off Measuring Information
Alpha-1-Fetoprotein (AFP)
Qual:
Quant: 2.20 ng/mL
Source: this donation
< 10 ng/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH163420
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Cancer-Antigen 19-9 (CA 19-9) - D37.70

Donor:
Gender: Female Age: 85
Diagnosed disease:
D37.70
Parameter:
Cancer-Antigen 19-9 (CA 19-9)
Donor:
Gender:
Female
Age:
85 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • D37.70
Parameter Result Ref. / Cut-Off Measuring Information
Cancer-Antigen 19-9 (CA 19-9)
Qual:
Quant: 84.00 U/mL
Source: this donation
< 39 U/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH167100
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Cancer-Antigen 125 (CA 125) - D39.1

Donor:
Gender: Female Age: 77
Diagnosed disease:
D39.1 - Neoplasm of uncertain or unknown behaviour of ovary
Parameter:
Cancer-Antigen 125 (CA 125)
Donor:
Gender:
Female
Age:
77 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Neoplasm of uncertain or unknown behaviour of ovary [D39.1]
Parameter Result Ref. / Cut-Off Measuring Information
Cancer-Antigen 125 (CA 125)
Qual:
Quant: 106.00 U/mL
Source: this donation
< 35 U/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH167118
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Prostate specific antigen (PSA), total - D40.0

Donor:
Gender: Male Age: 60
Diagnosed disease:
D40.0 - Neoplasm of uncertain or unknown behaviour of prostate
Parameter:
Prostate specific antigen (PSA), total
Donor:
Gender:
Male
Age:
60 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Neoplasm of uncertain or unknown behaviour of prostate [D40.0]
Parameter Result Ref. / Cut-Off Measuring Information
Prostate specific antigen (PSA), total
Qual:
Quant: 11.77 ng/mL
Source: this donation
< 4.4 ng/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH167270
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Prostate specific antigen (PSA), total - C79.5

Donor:
Gender: Male Age: 70
Diagnosed disease:
C79.5 - Secondary malignant neoplasm of bone and bone marrow
Parameter:
Prostate specific antigen (PSA), total
Donor:
Gender:
Male
Age:
70 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Secondary malignant neoplasm of bone and bone marrow [C79.5]
Parameter Result Ref. / Cut-Off Measuring Information
Prostate specific antigen (PSA), total
Qual:
Quant: 0.02 ng/mL
Source: this donation
< 4.4 ng/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH167277
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Prostate specific antigen (PSA), total - D40.0

Donor:
Gender: Male Age: 68
Diagnosed disease:
D40.0 - Neoplasm of uncertain or unknown behaviour of prostate
Parameter:
Prostate specific antigen (PSA), total
Donor:
Gender:
Male
Age:
68 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Neoplasm of uncertain or unknown behaviour of prostate [D40.0]
Parameter Result Ref. / Cut-Off Measuring Information
Prostate specific antigen (PSA), total
Qual:
Quant: 10.70 ng/mL
Source: this donation
< 4.4 ng/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH167307
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Cancer-Antigen 19-9 (CA 19-9) - D46.2

Donor:
Gender: Female Age: 80
Diagnosed disease:
D46.2 - Refractory anaemia with excess of blasts [RAEB]
Parameter:
Cancer-Antigen 19-9 (CA 19-9)
Donor:
Gender:
Female
Age:
80 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Refractory anaemia with excess of blasts [RAEB] [D46.2]
Parameter Result Ref. / Cut-Off Measuring Information
Cancer-Antigen 19-9 (CA 19-9)
Qual:
Quant: 58.70 U/mL
Source: this donation
< 39 U/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH167384
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Cancer-Antigen 125 (CA 125) - D39.1

Donor:
Gender: Female Age: 70
Diagnosed disease:
D39.1 - Neoplasm of uncertain or unknown behaviour of ovary
Parameter:
Cancer-Antigen 125 (CA 125)
Donor:
Gender:
Female
Age:
70 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Neoplasm of uncertain or unknown behaviour of ovary [D39.1]
Parameter Result Ref. / Cut-Off Measuring Information
Cancer-Antigen 125 (CA 125)
Qual:
Quant: 46.60 U/mL
Source: this donation
< 35 U/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH148253
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Prostate specific antigen (PSA), total - C79.5

Donor:
Gender: Male Age: 61
Diagnosed disease:
C79.5 - Secondary malignant neoplasm of bone and bone marrow
Parameter:
Prostate specific antigen (PSA), total
Donor:
Gender:
Male
Age:
61 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Secondary malignant neoplasm of bone and bone marrow [C79.5]
Parameter Result Ref. / Cut-Off Measuring Information
Prostate specific antigen (PSA), total
Qual:
Quant: 201.60 ng/mL
Source: this donation
< 4.4 ng/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH148329
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Cancer-Antigen 19-9 (CA 19-9) - C78.7

Donor:
Gender: Male Age: 63
Diagnosed disease:
C78.7 - Secondary malignant neoplasm of liver and intrahepatic bile duct
Parameter:
Cancer-Antigen 19-9 (CA 19-9)
Donor:
Gender:
Male
Age:
63 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Secondary malignant neoplasm of liver and intrahepatic bile duct [C78.7]
Parameter Result Ref. / Cut-Off Measuring Information
Cancer-Antigen 19-9 (CA 19-9)
Qual:
Quant: 2965.00 U/mL
Source: this donation
< 39 U/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH167399
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Cancer-Antigen 19-9 (CA 19-9) - C78.3

Donor:
Gender: Male Age: 55
Diagnosed disease:
C78.3 - Secondary malignant neoplasm of other and unspecified respiratory organs
Parameter:
Cancer-Antigen 19-9 (CA 19-9)
Donor:
Gender:
Male
Age:
55 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Secondary malignant neoplasm of other and unspecified respiratory organs [C78.3]
Parameter Result Ref. / Cut-Off Measuring Information
Cancer-Antigen 19-9 (CA 19-9)
Qual:
Quant: 86.60 U/mL
Source: this donation
< 39 U/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH167392
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Cancer-Antigen 19-9 (CA 19-9) - D39.1

Donor:
Gender: Female Age: 72
Diagnosed disease:
D39.1 - Neoplasm of uncertain or unknown behaviour of ovary
Parameter:
Cancer-Antigen 19-9 (CA 19-9)
Donor:
Gender:
Female
Age:
72 Years
Sample:
Matrix:
Serum
Condition:
hemolytic
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Neoplasm of uncertain or unknown behaviour of ovary [D39.1]
Parameter Result Ref. / Cut-Off Measuring Information
Cancer-Antigen 19-9 (CA 19-9)
Qual:
Quant: 48.50 U/mL
Source: this donation
< 39 U/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH148600
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Cancer-Antigen 19-9 (CA 19-9) - D37.70

Donor:
Gender: Male Age: 71
Diagnosed disease:
D37.70
Parameter:
Cancer-Antigen 19-9 (CA 19-9)
Donor:
Gender:
Male
Age:
71 Years
Sample:
Matrix:
Serum
Condition:
icteric
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • D37.70
Parameter Result Ref. / Cut-Off Measuring Information
Cancer-Antigen 19-9 (CA 19-9)
Qual:
Quant: 50.20 U/mL
Source: this donation
< 39 U/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH148593
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Cancer-Antigen 125 (CA 125) - C77.1

Donor:
Gender: Female Age: 66
Diagnosed disease:
C77.1 - Secondary and unspecified malignant neoplasm of intrathoracic lymph nodes
Parameter:
Cancer-Antigen 125 (CA 125)
Donor:
Gender:
Female
Age:
66 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Secondary and unspecified malignant neoplasm of intrathoracic lymph nodes [C77.1]
Parameter Result Ref. / Cut-Off Measuring Information
Cancer-Antigen 125 (CA 125)
Qual:
Quant: 36.30 U/mL
Source: this donation
< 35 U/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH148648
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Cancer-Antigen 19-9 (CA 19-9) - C79.88

Donor:
Gender: Female Age: 86
Diagnosed disease:
C79.88
Parameter:
Cancer-Antigen 19-9 (CA 19-9)
Donor:
Gender:
Female
Age:
86 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • C79.88
Parameter Result Ref. / Cut-Off Measuring Information
Cancer-Antigen 19-9 (CA 19-9)
Qual:
Quant: 59.50 U/mL
Source: this donation
< 39 U/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH148806
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Carcino Embryonic Antigen (CEA) - C77.1

Donor:
Gender: Female Age: 66
Diagnosed disease:
C77.1 - Secondary and unspecified malignant neoplasm of intrathoracic lymph nodes
Parameter:
Carcino Embryonic Antigen (CEA)
Donor:
Gender:
Female
Age:
66 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Secondary and unspecified malignant neoplasm of intrathoracic lymph nodes [C77.1]
Parameter Result Ref. / Cut-Off Measuring Information
Carcino Embryonic Antigen (CEA)
Qual:
Quant: 20.10 ng/mL
Source: this donation
< 4.6 ng/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH148581
0.5 mL (€81.25)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Cancer-Antigen 125 (CA 125) - C78.6

Donor:
Gender: Female Age: 76
Diagnosed disease:
C78.6 - Secondary malignant neoplasm of retroperitoneum and peritoneum
Parameter:
Cancer-Antigen 125 (CA 125)
Donor:
Gender:
Female
Age:
76 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Secondary malignant neoplasm of retroperitoneum and peritoneum [C78.6]
Parameter Result Ref. / Cut-Off Measuring Information
Cancer-Antigen 125 (CA 125)
Qual:
Quant: 110.70 U/mL
Source: this donation
< 35 U/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH148275
0.6 mL (€97.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Cancer-Antigen 125 (CA 125) - D39.1

Donor:
Gender: Female Age: 42
Diagnosed disease:
D39.1 - Neoplasm of uncertain or unknown behaviour of ovary
Parameter:
Cancer-Antigen 125 (CA 125)
Donor:
Gender:
Female
Age:
42 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Neoplasm of uncertain or unknown behaviour of ovary [D39.1]
Parameter Result Ref. / Cut-Off Measuring Information
Cancer-Antigen 125 (CA 125)
Qual:
Quant: 49.40 U/mL
Source: this donation
< 35 U/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH148607
0.6 mL (€97.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Cancer-Antigen 125 (CA 125) - C77.1

Donor:
Gender: Female Age: 66
Diagnosed disease:
C77.1 - Secondary and unspecified malignant neoplasm of intrathoracic lymph nodes
Parameter:
Cancer-Antigen 125 (CA 125)
Donor:
Gender:
Female
Age:
66 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Secondary and unspecified malignant neoplasm of intrathoracic lymph nodes [C77.1]
Parameter Result Ref. / Cut-Off Measuring Information
Cancer-Antigen 125 (CA 125)
Qual:
Quant: 39.80 U/mL
Source: this donation
< 35 U/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH148644
0.6 mL (€97.50)
Will be delivered in 16 to 20 Business Days (€180.00)

Human Serum - Carcino Embryonic Antigen (CEA) - C77.1

Donor:
Gender: Female Age: 66
Diagnosed disease:
C77.1 - Secondary and unspecified malignant neoplasm of intrathoracic lymph nodes
Parameter:
Carcino Embryonic Antigen (CEA)
Donor:
Gender:
Female
Age:
66 Years
Sample:
Matrix:
Serum
Condition:
perfect
Stored at:
< -18 degrees Celsius
Freeze-Thaw-Cycle:
0
Preanalytics:
Details:
centrifugation (10 min, 2500 x g = 3255 rpm, 20°C)
Diseases:
  • Secondary and unspecified malignant neoplasm of intrathoracic lymph nodes [C77.1]
Parameter Result Ref. / Cut-Off Measuring Information
Carcino Embryonic Antigen (CEA)
Qual:
Quant: 22.00 ng/mL
Source: this donation
< 4.6 ng/mL
Method: ECLIA (Electro Chemiluminescence Immuno Assay)
System: cobas Roche
Disclaimer
  • All products are for research or manufacturing purposes only and are not for direct therapeutic or diagnostic use in human or animals.
  • Biospecimens should be treated as potentially infectious. Each specimen is intended for use only in by qualified professionals who will safely handle and dispose of the products they receive.
  • Import permit for biological substances must be present for purchase.
  • This sample is not for molecular genetic studies.
CBH148577
0.6 mL (€97.50)
Will be delivered in 16 to 20 Business Days (€180.00)